9
Te Pari Sheep Jetter User Manual
Sheep Jetter
Trouble shooting guide
QUESTION
ANSWER
The nozzles are not spraying evenly or
the top nozzles are dripping a significant
amount between animal.
Check that the Jetter in on a level surface and the
valves are deactivating.
Check that the Jetter in on a level surface
and the valves are deactivating.
Check the pump is correctly primed, no air bubbles
are in the spray lines and nothing is restricting flow
from the tank.
The Jetter does not stop spraying even
without an animal in the Jetter.
Turn the “Power” switch “off” then back “on”. If this
does not fix the issue check nothing if between the
two sensors on each side of the Jetter.
Turn the “Power” switch “off” then back “on”. If this
does not fix the issue check nothing if between the
two sensors on each side of the Jetter.
Follow steps below
Remove the 4 x bolts
off the valve.
Open the valve up
There are two holes on the face
plate that need checking as well
To Clean:
Push fuse wire through
Spray water into hole
The blockage will be in either of
these two little holes