Statistics button
The statistics button shows the amount of dose left in the pack and the total number of doses administered. Each press scrolls
through the various items.
Volume of administered dose
Shows the total volume of dose administered.
Number of doses
Shows the total number of doses administered.
Clear stored statistics
With the screen displaying the clear icon, press the up or down arrow to select the tick or the cross. With the
tick highlighted, press the menu button. The display will return to the main menu, and the number of doses and
volume statistics will be reset to 0.
7
Te Pari Revolution Dosing Gun
www.tepari.com Freephone 0800 837 274
To Calibrate the Gun if giving incorrect dose
1. Press the stats and the power buttons
simultaneously
4. Press the menu button again and use
the up and down to set the % amount or
the ml. To save this, press menu again.
2. A screen with “Info, Calibration,
Features” will appear. Scroll to
“Calibration” and press menu.
5. Restart the gun and resume dosing.
3. Using up and down arrows, choose
percentage(%) or the ml as required.