PARTS OF THE UNIT ARE WORKING SLOWLY
Constricted, broken or punctured air lines
Compressor pressure is low
Check the airlines
Ensure no part of the unit is resting upon the airlines
REDUCTION IN AIR PRESSURE
Water trap filters
Check visually every 3 months and replaced as required
EYES ARE NOT WORKING
Dirty or broken eye
Eye cables broken or frayed
Clean and re-check, replace if required
Replace cable from autobox to eyes
THE INDICATOR DISPLAYS ------------
There is a problem with the loadbars
Contact the manufacturer
INDICATOR READ OUT IS FLUCTUATING OR NOT ZEROING
Plugs not completely connected
Plugs are damp
Battery is not adequately charged
Unit is damp
Electrical interference
Check the plug that goes over the loadbar collar is not
preventing the pins from engaging properly
Check loadbar cables are firmly in place, don’t over tighten
Check for moisture – clean with methylated spirits
Ensure dust caps are screwed together
Check battery charge state
Check indicator to unit cord
Electrical interference from a short on a electric fence
can affect your indicator
Battery and unit charges must be kept dry
NOT AUTOMATICALLY DRAFTING OR RELEASING
Comms cable fault
Incorrect indicator settings
Communication cable from indicator to unit is damaged
or has dirty terminals – clean terminals with CRC
Communications cable is in the wrong port
Check your indicator settings are correct
TRU-TEST INDICATOR DISPLAYS WAIT FOR TRIGGER
Dirty eyes
Faulty
Y
or Comms cable
Clean eyes
Check the
Y
and Communications cables and the
cables pins for damage, replace if required