Belden 1695A Coax Specifications
InterReach Spectrum Remote Access Unit Installation Guide
Page 21
TECP-77-222 • Issue
1 • August 2012
© 2012 TE Connectivity Ltd.
•
Use only RG‐6 CATV cable between the MRAU and SRAU, the lengths of which are listed below.
RG-6 Cable
Meters
Feet
Typical
2
6.56
800/900 iDEN to 850 CELL
6
19.68
800 AWS to 850 CELL
6
19.68
Belden
1695A
Coax
Specifications
Description
RG‐6/U type, 18 AWG solid 0.040‐inch bare copper conductor, plenum, foam FEP insulation,
Duofoil
®
+ tinned copper braid shield (95% coverage), Flamarrest
®
jacket.
Overall
Physical
Characteristics
Conductor
One
Coax
18
AWG
Solid
stranding
Bare
Copper
(BC)
conductor
material
0.040
‐
inch
diameter
Insulation
Teflon
®
Foam
Fluorinated
Ethylene
Propylene
(FFEP)
0.170
‐
inch
diameter
Outer
Shield
Layer
1
Duofoil
®
Tape
Aluminum
Foil
‐
Polyester
Tape
‐
Aluminum
Foil
100%
coverage
Outer
Shield
Layer
2
Braid
Tinned
Copper
(TC)
95%
coverage
Outer
Jacket
Flamarrest
®
Low
Smoke
Polyvinyl
Chloride
(LS
PVC)
Overall
Cabling
0.234
‐
inch
overall
nominal
diameter