background image

408- 10271

3

of 5

Rev

D

Figure 2

285 mm [11.2 in.]

168 mm

[6.6 in.]

9.6 mm [.38 in.] (4 Places)

Mounting Dimensions

90

_

Vertical

0

_

Horizontal

Mounting Angle

Before system assembly is complete, ensure that:

a. the combiner box assembly and exposed

wiring is located in an area that is NOT readily

accessible, such as a roof top or behind a fence

or barrier, at least 0.914 m [3 ft] above ground

level
b. the location surface ranges from 0

_

horizontal

to 90

_

vertical

c. the combiner box assembly is oriented with

the hinges at the top, right, or left
d. there is enough clearance at the front and

above the hinges of the combiner box assembly

to open the cover and below the connectors for

mating and unmating connectors, and

approximately 25.4 mm [1 in.] on all 4 sides of

the combiner box assembly for ventilation
e. the location does not have continuous water

flow or extreme temperature changes
f. the location ambient temperature is a

maximum of 50

_

C [122

_

F]

g. the combiner box assembly is in the shade

(this is recommended)

After system assembly is complete, ensure that:

the combiner box and exposed wiring for

connection to the combiner box PV input strings

via the SOLARLOK connectors is located in an

area that is NOT readily accessible, such as a

roof top or behind a fence or barrier

3.2. Ground the Equipment (If Required)

Grounding the equipment is the responsibility of the

installer. Ensure that the ground wire is not nicked,

cut, or scraped.
Refer to Figure 3, and proceed as follows:

A size 8 AWG copper wire is installed between

the grounding assembly and the equipment

ground terminal block.

1. Remove the wire binding hex nut from the wire

grounding assembly.
2. Position the ground wire into the wire slot of the

ground bolt.
3. Thread the wire binding hex nut onto the ground

bolt. Finger--tighten the wire binding hex nut until

the wire is compressed.
4. Using a

9

/

16

--in. open end wrench, hold the hex

body of the ground bolt, and using a

5

/

8

--in. socket

wrench, tighten the wire binding hex nut to a torque

of 5.08 N--m [45 in.--lbs.].

For additional information on the wire grounding

assembly, refer to Instruction Sheet 408--10262.

Figure 3

Wire

Wire Slot of

Ground Bolt

Wire Binding

Hex Nut

Hex Body of

Ground Bolt

Optional Grounding

3.3. Connect Wiring and Install Fuses

1. Using a cross--recessed screwdriver, remove

the two cover screws opposite the hinge, then

remove the two remaining cover screws. Pivot the

cover open.

NOTE

i