Connector Mating

Locking Latch and 

Locking Tab Engaged

Housings in Closed Position

Housing in 

Closed Position

Locking Latch and 

Locking Tab Engaged

408-3393

3 of 3

Rev B

Figure 5

4. DISASSEMBLY PROCEDURE

4.1. Unmating Connectors

Depress the locking latch of the housing and pull the 
housing straight away from the mating connector. See 
Figure 6.

Depress Locking Latch Here

Pull Straight Away

Figure 6

!

CAUTION

4.2. Extracting Contacts

To prevent damage to the connector, the housing 

must be in the open position before removing any 

contacts.

!

CAUTION

1. Deflect the latching ears one at a time, then 
lightly pull the wire end of the housing away from 
the housing until the first tooth of the latching arms 
engage. See Figure 7.

Take care not to over deflect the latching ears.

Contact Extraction

Housing in 

Open Position

Contact

 Insulation Barrel

Pull

Latching Ear 

(Ref)

Disengaged Housing 

Cone Fingers

Second Tooth of 

Latching Arm Engaged

2. Grasp the contact insulation barrel and pull it 
using a twisting motion until the contact is free from 
housing. Refer to Figure 7.

Figure 7

5. REPLACEMENT AND REPAIR

The connectors and contacts are not repairable. 

DO NOT use defective or damaged product. DO NOT 
re-use the contacts by removing the wire.

6. REVISION SUMMARY

Revisions to this instruction sheet include:

Changed company name and logo

Added Section 5