Connector Mating
Locking Latch and
Locking Tab Engaged
Housings in Closed Position
Housing in
Closed Position
Locking Latch and
Locking Tab Engaged
408-3393
3 of 3
Rev B
Figure 5
4. DISASSEMBLY PROCEDURE
4.1. Unmating Connectors
Depress the locking latch of the housing and pull the
housing straight away from the mating connector. See
Figure 6.
Depress Locking Latch Here
Pull Straight Away
Figure 6
!
CAUTION
4.2. Extracting Contacts
To prevent damage to the connector, the housing
must be in the open position before removing any
contacts.
!
CAUTION
1. Deflect the latching ears one at a time, then
lightly pull the wire end of the housing away from
the housing until the first tooth of the latching arms
engage. See Figure 7.
Take care not to over deflect the latching ears.
Contact Extraction
Housing in
Open Position
Contact
Insulation Barrel
Pull
Latching Ear
(Ref)
Disengaged Housing
Cone Fingers
Second Tooth of
Latching Arm Engaged
2. Grasp the contact insulation barrel and pull it
using a twisting motion until the contact is free from
housing. Refer to Figure 7.
Figure 7
5. REPLACEMENT AND REPAIR
The connectors and contacts are not repairable.
DO NOT use defective or damaged product. DO NOT
re-use the contacts by removing the wire.
6. REVISION SUMMARY
Revisions to this instruction sheet include:
•
Changed company name and logo
•
Added Section 5