3. Prepare the panel with a cutout meeting the dimensions given in Figure 3.
PANEL THICKNESS (mm [in.]) ±0.10 [±.004]
RECEPTACLE
SIZE
PANEL CUTOUT DIMENSION (mm [in.])
Number of Receptacle Panel Gasket Identifiers
A (Width)
B (Height)
±
0.03 [
±
.001]
MINIMUM PITCH (Centerline)
2
3
4
C (Vertical)
D (Horizontal)
1.27 [.05]
1.60 [.06]
2.03 [.08]
3
10.85±0.08
[.42±.003]
8.95 [.3523]
12.8 [.503]
14.3 [.562]
6
11.49 [.4523]
15.34 [.604]
9
14.03 [.5523]
17.88 [.704]
Figure 3
4. From the back of the panel, align the receptacle mating face with the cutout so that the mating latch
faces the bottom of the panel cutout, then insert the receptacle into the cutout until the panel latches
snap into the panel cutout. Ensure that all panel gasket pads are against the panel. See Figure 4.
NOTE
In order for the release button of the plug to face the top of the panel cutout, the receptacle mating latch must face the bottom
of the panel cutout when the receptacle is mounted to the panel.
Figure 4
5. With the mating face of the plug facing the mating face of the receptacle, align the orientation keys
with the receptacle orientation keyways, and push the plug onto the receptacle until it stops. See
Figure 4.
Back of Panel
Panel Gasket Pads
(4 Places) Against Panel
Mating Face
of Receptacle
Receptacle
Mating Latch
Mating Face
of Plug
Bottom of Panel Cutout
Plug Release Button
Facing Top of Panel Cutout
Note:
For clarity, wires
are not shown.
Top of Panel Cutout
Orientation
Keyway
R 0.60 mm [.023 in.] Max
B
Note:
Not to Scale
C
A
D