TE Connectivity CEELOK FAS-T Instruction Sheet Download Page 2

408-32046

2 of 6

Rev A

Figure 5

3. Untwist the conductor pairs and strip to the length 
of approximately 3.18 ±0.76 mm [.125 ±.030 in.]. 
Terminate pins (2102349-3) or sockets (2102350-5) 
to the conductors using crimp tool M22520/2-01 
with positioner K1850. Refer to Figures 6 thru 8.

Figure 6

Figure 7

Figure 8

4. Re-twist wires to include two full twists prior to 
inserting them into the connector housing. Insert the 
contact into the circuit cavity and push it into the 
cavity until it “clicks” into place. During insertion, 
care should be taken to make sure the conductor 
pairs are loaded into adjacent circuit cavities.

For example, one pair should be loaded into cavities 
(1 and 2), another pair in cavities (3 and 4), another 
pair in cavities (5 and 6), and another pair in cavities 
(7 and 8). If it is difficult to seat the contacts by 
hand, the insertion tip of tool DHK696 can be used. 
The tip will push on the rear of the crimp barrel of 
the contact. Refer to Figures 9 thru 12.

Figure 9

Figure 10

Figure 11

3.18 ±0.76 

[.125 ±.030]

Socket 

2102350-5

Pin 

2102349-3