Page 56 / 101 ECOC: EGC0 ; LOC: AI
528050-1
412-18876 Rev. G
12
Maintenance
DANGER!
Due to the risk of hand or finger injury, never try to reach into the machine before
having assured that the machine is disconnected from the air supply.
CAUTION!
The compressed air connection tube must not be longer than 1 m and has to have a
coupling connection.
Before starting maintenance, disassembly or repair work, the crimp machine must
be disconnected from air supply.
When working with the Pneum. Parallel Crimp Machine AT-SC, do not wear loose
clothing, jewellery or long, loose hair that can get caught in the Pneum. Parallel
Crimp Machine AT-SC.
The crimp machine is only allowed to be used when it is in complete functional
condition.
The crimp machine is only allowed to be used with mounted adapter and die set.
Work with caution.
Maintenance work may be performed only by authorized and properly trained
personnel.
12.1
Maintenance Plan
DANGER!
Due to the risk of hand or finger injury, never try to reach into the machine before
having assured that the machine is disconnected from the air supply.
CAUTION!
Before starting maintenance, disassembly or repair work, the crimp machine must
be disconnected from air supply.
Wear protective gloves and safety glasses during lubrication work. Please pay
attention to the safety instructions in the “safety data sheet” of the grease.
Summary of Contents for AT-SC
Page 32: ...Page 32 101 ECOC EGC0 LOC AI 528050 1 412 18876 Rev G 17 3 Pneumatik Schema Abb 17 02...
Page 65: ...Page 65 101 ECOC EGC0 LOC AI 528050 1 412 18876 Rev G 17 3 Pneumatic Diagram Fig 17 02...
Page 98: ...Page 98 101 ECOC EGC0 LOC AI 528050 1 412 18876 Rev G 17 3 Sch ma Pneumatique Fig 17 02...