409-1950
Rev G
14
of 22
If Using the Multi-Directional Valve (Foot Control Must Be Used)
Refer to Figure 7.
1. Attach one end of a hose assembly to the pump and the other end to the multi-directional valve.
2. Attach one end of each hose assembly to the multi-directional valve and the other end of each
hose assembly to a crimping head according to 408-1208.
3. Plug the foot control into the pump.
4. If any crimping head does not contain dies, install a die assembly onto the crimping head
according to the instructions included with the crimping head.
Figure 7: Using the multi-directional valve
4.5.
Disconnecting Accessories
Before removing any accessory from the pump or a hose assembly, ALWAYS depress the DUMP switch to
release the pressure from the system, then DISCONNECT the pump from the power supply.
CAUTION
To avoid personal injury, ALWAYS release the pressure from the system, then DISCONNECT the pump from the power
supply before disconnecting an accessory from the pump or a hose assembly.
Protector caps are assembled onto crimping heads and hose fittings to prevent dit from entering the hydraulic
system. Ensure that protector caps are placed on quick-disconnect couplers when accessories are
disconnected.