![TE Connectivity 549 AC Installation And Operating Instructions Download Page 3](http://html1.mh-extra.com/html/te-connectivity/549-ac/549-ac_installation-and-operating-instructions_3922582003.webp)
A
B
C
D
H
E
I
J
K
in
mm
A
1.86
47.3
B
1.60
40 .8
C
0 .47
12.0
D
1.74
44.4
E
0 .70
17.8
F
0 .87
22.1
G
0 .99
12.0
H
0 .51
13.0
I
0 .16
4.0
J
K
1.0 8
27.5
1.18
30 .0
PAN EL CU T-O U T 2
PAN EL CU T-O U T 1
D
A
E
B
C
(U SE AD APTO R RIN G)
AD APTO R RIN G
F
G
in
mm
A
1.20
30 .5
B
0 .57
14.5
C
0 .25
6.40
D
1.0 9
27.8
E
0 .15
3.9
GU ID E N O TES FO R U SIN G SU PPLIED FITTIN G KIT.
1) PLACE IN STRU M EN T IN PAN EL CU TO U T.
2) FIT AD APTO R RIN G , IF U SIN G CU TO U T 1.
3) FIT RETAIN IN G RIN G, EN SU RIN G TABS ARE ALIGN ED AS SH O W N .
(APPRO X 45 D EGREE AN GLE RELATIVE TO GRO O VES IN CASE)
4) IM PO RTAN T - N U T 'A' IS U SED FO R FACTO RY ASSEM BLY O N LY AN D
M U ST N O T BE TAM PERED W ITH D U RIN G IN STALLATIO N .
5) FIT N U T 'B', EN SU RIN G A N O M 3mm GAP IS LEFT BETW EEN IT AN D N U T 'A'
6) FIT W ASH ERS PRIO R TO AN D AFTER CO N N ECTIO N W IRES.
7) FIT N U T 'C'.
8) EN SU RE N U T 'B' IS REFRAIN ED FRO M M O VEM EN T.
9) N U T 'C' SH O U LD N O W BE TIGH TEN ED .
RETAIN IN G RIN G
RETAIN IN G RIN G
AD APTO R RIN G
A BC
IM PO RTAN T
SEE N O TES 4 - 9
Connection Diagram
N
L
Reference Conditions of Influence Quantities
Influence Quantities are variables that affect measurement errors
to a minor degree. Accuracy is verified under nominal value
(within the specified tolerance) of these conditions.
Ambient temperature
23°C ±2°C
Input waveform
60Hz ± 0.5%
Input waveform
Sinusoidal
(distortion factor <0·005)
Magnetic field of external
origin
Terrestrial flux
Environment
Operating temperature
-10°C to +55°C
*
Storage temperature
-30°C to +85°C
*
*
Maximum operating and storage temperatures are in the context
of typical daily and seasonal variation.
Relative humidity
0 to 95%, non-condensing
Altitude
Up to 2000m
Vibration
10Hz to 50Hz, IEC 60068-2-6, 2g
Shock
30g in 3 planes
Mechanics
Dimensions
40.80x47.25x59.25mm (h x w x d)
1.60”x 1.86”x2.33” (h x w x d)
Depth (behind panel) 2.36” (60 mm) maximum
Case protrusion
(front of panel)
0.48” (12.2 mm) maximum
Sealing
IP52 (front panel), IP30 (case) (minimum)
Approval, Certification, and Standards Compliance
EMC, Emissions
FCC Part 15
Safety
UL 61010-1:2
nd
edition.
While TE Connectivity (TE) has made every reasonable effort to ensure the accuracy of the information in this catalogue, TE does not guarantee that it is error-free, nor does TE make any other
representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time
without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a
particular purpose. The dimensions in this catalogue are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications. TE Connectivity and TE connectivity (logo) are trademarks. CROMPTON is a trademark of Crompton Parkinson Limited and is used under
licence. Other products or company names mentioned herein may be trademarks of their respective owners.
Tyco Electronics UK Ltd
Registered office:
A TE Connectivity company
Faraday Road, Dorcan
Freebournes Road,
Swindon, SN3 5HH
Witham, CM8 3AH, UK
Reg. No. 550 926
Tel: +44 (0) 1376 509509
Fax: +44 (0) 1376 509511
www.crompton-instruments.com
www.energy.te.com
Project 2208. Drawing No. CI-3K68901 Rev.K DMR 2777 28/02/13