5.5. Ratchet Inspection

The CERTI-CRIMP tool ratchet should be checked to 

ensure that the ratchet does not release prematurely, 

allowing the jaws to open before they have fully 

bottomed. Obtain a 0.025 mm [.001 in.] shim suitable 

for checking the clearance between the bottoming 

surfaces of the crimping jaws. Proceed as follows:

1. Select a terminal or splice, and properly 

stripped 

wire with 

maximum 

wire load (such as wire 

size 16 

AWG and size 22-16 terminal).

2. Position the terminal or splice and wire 

between the crimping jaws, as described in 

Section 3.

3. Hold the wire in place and squeeze the 

handles until the CERTI-CRIMP tool ratchet 

releases. Hold the handles in this position, 

maintaining just enough tension to keep the jaws 

closed.

Suggested Plug Gage Design

Jaw Closure 

Configuration

NO-GO

Dim