2. .Lubricate the ram if necessary with a THIN coat 
of high-pressure grease. DO NOT lubricate 
excessively. Store in a clean, dry area.

CAUTION

 

Be sure to keep the termination areas of the stuffers and 

nest areas especially clean. DO NOT oil or grease the 

termination areas of the stuffers.

8.2. Periodic Inspection

Personnel responsible for the terminator should 
perform regular inspections, record the results, and 
keep a record of inspections with the terminator.

It is recommended that inspection procedures be 
performed at least once a month. Work environment, 
company standards, or amount of terminator use may 
dictate more frequent inspections.

CAUTION

 

Failure to perform periodic inspection and daily 

maintenance can cause the terminator to make 

defective terminations leading to discontinuities on 

individual wire circuits.

9. REPLACEMENT AND REPAIR

Order replacement parts through your representative, 
or call 1-800-526-5142, or send a facsimile of your 
purchase order to 717-986-7605, or write to:

CUSTOMER SERVICE (038-035)

 

TYCO ELECTRONICS CORPORATION

 

PO BOX 3608

 

HARRISBURG PA 17105-3608

For customer repair service, call 1-800-526-5136.

10. STORAGE

If the tool is not used, it must be stored by taking the 
following precautions:

1. Store the tool indoors.

2. Grease unpainted parts.

3. Protect this tool from knocks or stresses.

4. Protect this tool from high levels of humidity and 
from big temperature changes.

5. Prevent the tool from coming into contact with 
corrosive substances.

11. DECOMMISSIONING

In compliance with the regulations in force in the 
country where the tool is used, the user must make 
sure that waste produced during operation is correctly 
disposed of. Disposal of lubricants and parts removed 
must be carried out in compliance with the standards 
in force in the country where the tool is used.

12. REVISION SUMMARY

Since the previous release of this document , the 
document format was revised and the software was 
translated.

Contact Crimp Height

 

6.02 ± 0.13 [.237 ± .005]

Contact

“A”

End of Wire Circuit

End of Conductor

MODULAR 

PLUG TYPE

DIM. A

(Wire Insertion 

Depth)

Standard and

Small Conductor

0.00-0.64

[.000-.025]

High 

Performance

(Category 5)

0.00-0.25

[.000-.10]

Figure 5

!

!

Summary of Contents for 354711-1

Page 1: ...d with each modular plug single terminator See Figure 1 NOTE Modular Plug Single Terminator 354711 1 does not include a tooling kit Tooling kits consisting of a contact inserter strain relief stuffer...

Page 2: ...ication equipment NEVER insert hands into installed application equipment NEVER alter modify or misuse the application equipment TOOLING ASSISTANCE CENTER CALL TOLL FREE 1 800 722 1111 CONTINENTAL UNI...

Page 3: ...n not in use when performing maintenance on the tool or when clearing a jammed tool 408 9919 3 of 7 Rev G DANGER Denotes an imminent hazard which may result in moderate or severe injury CAUTION Denote...

Page 4: ...ax To Tool Lubricator Check Oil Level Regularly Adjust to Very Fine Mist 1 Secure the machine to the bench with two M4 or 8 32 bolts or lag screws 2 Blow air through the air hose to remove any foreign...

Page 5: ...the adjusting screws several turns until they begin sliding the stuffers against the locking setscrews 8 Securely tighten the stuffer locking screws 9 Adjust the tooling for correct strain relief oper...

Page 6: ...n FCC regulations The primary strain relief is in the latched position without apparent damage or cutting the cable insulation Wires are inserted into the correct cavities to within the dimensions giv...

Page 7: ...7 986 7605 or write to CUSTOMER SERVICE 038 035 TYCO ELECTRONICS CORPORATION PO BOX 3608 HARRISBURG PA 17105 3608 For customer repair service call 1 800 526 5136 10 STORAGE If the tool is not used it...

Reviews: