409-32023
Rev
B
41 of 41
Troubleshoot the feeder as described in Figure 62.
PROBLEM
PROBABLE CAUSE
REMEDY
Feeder does not read data correctly.
Dirt shorting out applicator memory.
Remove memory and clean.
Feeder removed before data transfer is
complete.
Reconnect and allow time for the displayed
message on the machine to close.
Feed finger does not align with track.
Mis-adjustment of feeder amount bracket.
Loosen bracket then install feeder moving
assembly until the feed finger aligns
correctly. Carefully remove feeder and
tighten mounting hardware.
Terminal feed position changes between
terminators/machines.
Calibration not performed exactly the same
between machines.
Perform feeder calibration on both machines.
Terminals is not being properly fed.
Retract position is set too short.
Adjust retract position until feed finger
properly picks up feed index hole. May need
to test feed at speed.
Figure 62
6.3.
Clearing Jammed Terminal Strip
1. Turn off the power to the system III precision controller.
DANGER
Make sure to turn off the system III precision controller (in addition to powering down the bench top terminator or leadmaker)
prior to clearing a jam. Otherwise, injury is possible.
2. Clear the jam (refer to the respective machine customer manual).
3. Turn the system III precision controller back on.
4. Position the terminal over the anvil.
5. Resume production.
6.4.
Precision Controller Maintenance
There are no serviceable components in the precision controller. If the unit fails, contact Tooling Assistance
Center at 1-800-722-1111 for troubleshooting assistance or information regarding the component repair center.
DANGER
Under the right conditions, the servo drive controller in the precision controller will reach a temperature capable of causing
burns. Do not open the controller.
7.
RESTRICTION ON HAZARDOUS SUBSTANCES (RoHS) INFORMATION
Information on the presence and location of any substances subject to RoHS can be found at
http://www.te.com/customersupport/rohssupportcenter
Click the Resources tab, click Check Product Compliance, enter the terminator part number then click “Search”.
8.
REVISION SUMMARY
Revisions to this customer manual include:
Modified step 1 of Paragraph 2.3 and step 1 of Paragraph 2.3, A
Updated search information in Section 7
Downloaded From