409-10104
Rev E
17
of 18
5 Troubleshooting
If the red LED is flashing or an audible alert sounds, refer to Table 5 for problems, probable causes,
and remedies. If the problem cannot be resolved by the action recommended in Table 5, contact TE
Field Service (see section 6,
If the tool loses oil, contact the Tooling Assistance Center. Do not open the tool or damage the seal of
the tool.
If the red LED flashes three times and simultaneously three audible alert warning signals occur (see
Table 5). A serious fault has occurred. If this fault occurs repeatedly, contact TE Field Service. Do not
open the tool or damage the seal of the tool.
Table 5: Troubleshooting
Red LED
White
LED
Audible
alert
When
Why
20 sec
After working cycle
Low battery charge
After inserting battery
Self-check
20 sec/2 Hz
After working cycle
Service required
20 sec/2 Hz
While exceeding
temperature limit
Unit is too hot
20 sec
20 sec/2 Hz
After working cycle
Service required
1 x
Error:
Required pressure not
achieved. Operator interrupted
crimping cycle while motor was
running.
3 x
3 x
Serious error:
Required pressure
not achieved while motor was
running