Piezo Haptic Actuators - PowerHap
Z63000Z2910Z1Z44
Application note for evaluation kit 60 V
Preliminary data
PPD PI AE/IE PD
2019-05-08
Please read Cautions and warnings and
Page 18 of 28
Important notes at the end of this document.
These variables only have an effect when in TDK mode (SW1 OFF).
5.4.4 Response type
1. In PSoCCreator, go to project “BOS1901_Test”, then go to folder “Header Files” and open file
“sensing_button_data.h”
2. Edit the #define variables values in section “Response type”.
RESPONSE_TYPE_CLICK_PRD changes number of sine wave period on single click feedback
(press-release feedback on both channels, low pressure of multipress feedback on channel B).
RESPONSE_TYPE_SMALL_PRD changes number of sine wave period on small feedback
(medium pressure of multipress feedback on channel B).
RESPONSE_TYPE_LONG_PRD changes number of sine wave period on long feedback (high
pressure of multipress feedback on channel B).
3. Save the project and upload the new firmware.