background image

 

 

 

Piezo Haptic Actuators - PowerHap  

Application note for evaluation kit 60 V 

Series/Type:

 

 

 

Ordering code:   

Z63000Z2910Z1Z44 

Date: 

 

2019-05-08 

Version: 

 

1.6 

 TDK Electronics AG 2019. Reproduction, publication and dissemination of this publication, enclosures hereto and the 

information contained therein without TDK Electronics' prior express consent is prohibited. 

Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then 
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.  
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! 

Identification/Classification 1  
(header 1 + top left bar): 

Piezo Haptic Actuators - PowerHap 

Identification/Classification 2  
(header 2 + bottom left header bar): 

Application note for evaluation kit 60 V 

Ordering code: (top right header bar) 

Z63000Z2910Z1Z44 

Series/Type: (bottom right header bar) 

 

Preliminary data (optional):  

Preliminary data 

Department: 

PPD PI AE/IE PD 

Date: 

2019-05-08 

Version: 

1.6 

Prepared by: 

Roman Puchleitner 

Signed by: 

Harald Kastl, Andreas Pentscher-Stani, Roman Puchleitner 

Summary of Contents for PowerHap

Page 1: ...change the color to white This ensures that the table disappears invisible for the customer PDF Don t change formatting when entering or pasting text in the table and don t add any cell or line in and...

Page 2: ...ators 9 3 3 DIP switch settings 10 3 4 Output configuration options 12 3 4 1 Differential output configuration 12 3 4 2 Single ended output configuration 12 3 5 Breakable units 13 4 Software 13 4 1 So...

Page 3: ...aluation kit 60 V Preliminary data PPD PI AE IE PD 2019 05 08 Please read Cautions and warnings and Page 3 of 28 Important notes at the end of this document 9 Document history 25 Cautions and warnings...

Page 4: ...peration over the whole operation temperature range or lifetime This evaluation kit provided by TDK is intended to be used for functional testing only Due to their purpose evaluation driver kits are n...

Page 5: ...actuators included in the kit 1 pcs each with wire o 0909H011V060 previously known as 2 5 G o 0904H014V060 previously known as Lateral Mini 9 x 3 75 o 1204H018V060 previously known as Lateral Mini 12...

Page 6: ...er board BOS1901 evaluation PCB 2 USB cable Micro USB cable to connect the evaluation PCB to a computer 3 TDK piezo actuator 0909H011V060 previously known as 2 5 G part number Z63000Z2910Z 1 Z2 4 TDK...

Page 7: ...annel on P2A or P2B connector Connect the evaluation PCB to a computer using the included USB cable then wait for LED D1 green to light up and LED D2 red to turn off after the firmware identification...

Page 8: ...N SB2 SB3 SB1x Refer to the section of the jumper settings for details and limitations 3 1 1 Use BAT power external power supply connection From default state Remove power to the evaluation PCB by unp...

Page 9: ...n one or both SB1X depending on the choice of UPI configuration Plug the USB cable to the evaluation PCB wait for LED D1 green to light up and LED De red to turn off 3 2 Piezo actuators TDK PowerHap p...

Page 10: ...maximum and minimum values allowable for the selected range It does not affect the gain and offset conversion between the input signal and the output voltage If the requested voltage is out the range...

Page 11: ...s the amplitude level of the feedback response Setting SW6 to ON will provide a stronger response than setting it to OFF SW6 has an effect only in press release mode SW7 SW7 sets the sensitivity level...

Page 12: ...p actuators with the DIP switches Figure 3 Two terminal differential output configuration 3 4 2 Single ended output configuration The single ended output configuration allows to drive up to two differ...

Page 13: ...lease follow the Audacity installation procedure The software is free of use and can be found at https www audacityteam org download Refer to https www audacityteam org about license for the terms of...

Page 14: ...9 If starting a new project make sure to use a Project Rate at 8 kHz lower left corner field 10 For other Audacity features please refer to the software help 5 Firmware 5 1 Identifying the firmware r...

Page 15: ...previous section and end with green LED on and red LED off If red LED does not turn off wait a couple of seconds then press and release RST again 3 When the USB HID State field reads Connected press o...

Page 16: ...orkspace Explorer right click on Project USBFS_Bootloader then choose Build USBFS_Bootloader 3 In the Workspace Explorer right click on Project BOS1901_Test then choose Build BOS1901_Test 4 The compil...

Page 17: ...K_TDK_CIRC When SW6 is OFF the feedback amplitude is set to LOW_AMP_MULTIPLICATOR times HIGH_AMP_PRESS_FEEDBACK_TDK_CIRC HIGH_AMP_RELEASE_FEEDBACK_TDK_CIRC changes the release feedback intensity When...

Page 18: ...r Files and open file sensing_button_data h 2 Edit the define variables values in section Response type RESPONSE_TYPE_CLICK_PRD changes number of sine wave period on single click feedback press releas...

Page 19: ...ion note for evaluation kit 60 V Preliminary data PPD PI AE IE PD 2019 05 08 Please read Cautions and warnings and Page 19 of 28 Important notes at the end of this document 6 Design reference 6 1 Sche...

Page 20: ...Z63000Z2910Z1Z44 Application note for evaluation kit 60 V Preliminary data PPD PI AE IE PD 2019 05 08 Please read Cautions and warnings and Page 20 of 28 Important notes at the end of this document Fi...

Page 21: ...r evaluation kit 60 V Preliminary data PPD PI AE IE PD 2019 05 08 Please read Cautions and warnings and Page 21 of 28 Important notes at the end of this document 6 2 PCB Layout Figure 9 Layout view to...

Page 22: ...luation kit 60 V Preliminary data PPD PI AE IE PD 2019 05 08 Please read Cautions and warnings and Page 22 of 28 Important notes at the end of this document Figure 11 Layout view bottom layer mirrored...

Page 23: ...10 nF CAP CER 10000PF 200V X7R 0603 C3 C4 C5 C6 C7 C9 6 1 F CAP CER 1UF 10V X6S 0402 C3A C3B C4A C4B C5A C5B C8 C12 C14 C16 C18 11 0 1 F CAP CER 0 1UF 25V X5R 0402 C19 1 33 F CAP ALUM 33UF 20 10V RADI...

Page 24: ...th overvoltage and or overcurrent protection is highly recommended This product uses semiconductors that can be damaged by electrostatic discharge ESD When handling care must be taken so that the devi...

Page 25: ...ment history ISSUE DATE CHANGES 1 6 May 2019 Formatting changed 1 5 May 2019 Default settings in table 3 changed 1 4 April 2019 Compatibility with Apple and Linux systems Signal to voltage gain and of...

Page 26: ...ors Even when they are disconnected from a supply the electrical energy content of a loaded actuator can be high and is held for a long time Always ensure a complete discharging of an actuator e g via...

Page 27: ...bserved 4 In order to satisfy certain technical requirements some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions e g because they...

Page 28: ...ld MiniBlue MiniCell MKD MKK MotorCap PCC PhaseCap PhaseCube PhaseMod PhiCap PowerHap PQSine PQvar SIFERRIT SIFI SIKOREL SilverCap SIMDAD SiMic SIMID SineFormer SIOV ThermoFuse WindCap are trademarks...

Reviews: