background image

5

A series of products that offer a fully, tightly regulated 
output for powering 8.3, 9.6 or 12V intermediate bus 
architectures, overcoming shortcomings when using 
unregulated converters and allowing full telecom input 
voltage range operation, without compromise.

Quarter Brick

The addition of the iQG product series enhances the  
product line up by offering even greater useable output 
power and improved efficiency with limited airflow and high 
operating temperatures. A further benefit is the  
capability to increase the power rating to 800W by  
operating two modules in parallel using the built in ‘droop 
output’ regulation technique.

• 1500V basic isolation
• 13.2 mm tall (12.7 mm no baseplate)
• No baseplate option
• Monotonic start - up
• Starts into pre - biased load
• Constant switching frequency
• Pin length choice
• Positive or negative on / off logic choice
• Latching / non latching protection options
• Current share version, droop technique

Series 

            

iQG

iQL

  Warranty 

                  3 years                                                                          3 years

  Format, DOSA 

                 open frame           

         open frame

  Industry standard                   quater brick, thru hole           quater brick, thru hole
  Baseplate    option 

          option

  Output voltage 

                  9.6V, 12V 

             8.3V, 9.6V, 12V

  Input voltage range                 36 – 75V               

       36 – 75V

  Output trim feature                  no  

 

         

       yes

  Remote sense feature             no  

 

         

       no

  Efficiency                                 upto 96 %                       

 

       upto 95 %

  Output current / power 

  upto 33A / 400W         

 

 

       upto 30A / 300W

DC/DC converters, intermediate 
bus architecture – isolated, 
regulated output

NEW

Summary of Contents for Power Supply/DC to DC Converter/CCFL...

Page 1: ...APPLICATION GUIDE...

Page 2: ...rise of intelligent products today s electronics industry is on the verge of an unprecedented new era TDK Lambda will continue to provide solid support for this ever widening range of new applications...

Page 3: ...formance quality and cost the designer is able to engineer an energy efficient cost effective and reliable distributed power architecture system to address the most demanding of needs in todays evolvi...

Page 4: ...zero airflow these POLs are ideal for all applications Very low profile 3A only 3 45 mm tall Very high efficiency upto 96 5 No Tuning required Can source or sink current Positive or negative on off lo...

Page 5: ...c choice Sequencing options SMT or SIP package choices Input Voltage Range 3 0 to 5 5V Input Voltage Range 6 0 to 14 0V Series iBA iAA Output current power 8A 26 W 15A 50W Efficiency upto 97 upto 97 O...

Page 6: ...the built in droop output regulation technique 1500V basic isolation 13 2 mm tall 12 7 mm no baseplate No baseplate option Monotonic start up Starts into pre biased load Constant switching frequency...

Page 7: ...Pin length choice Isolated remote on off Current share option droop technique Series iFB Warranty 3 years Format DOSA open frame Industry standard full brick thru hole Baseplate option Output voltage...

Page 8: ...lation Very low profile contact cooling compatibility Output voltage adjustment trim range Remote sense Monotonic start up starts into pre biased load Starts into pre biased load Constant switching fr...

Page 9: ...t voltage adjustment trim range Remote sense Monotonic start up Starts into pre biased load Constant switching frequency Pin length choice Positive or negative on off logic option Series iSA iSF iSF W...

Page 10: ...uency Pin length choice SMT options Positive or negative on off logic option Series iEE iEE4W Warranty 3 years 3 years 3 years 2 years Format DOSA open frame open frame open frame open frame Industry...

Page 11: ...frequency Pin length choice Positive or negative on off logic option Series PAQ Warranty 2 years 3 years 3 years 3 years Format DOSA open frame open frame open frame open frame Industry standard B bri...

Page 12: ...tive on off logic option Current share option droop technique Series iHG PAH300 450 Warranty 3 years 2 years Format DOSA open frame closed open frame Industry standard 1 2B brick thru hole 1 2B brick...

Page 13: ...7 6 x 50 8 x 14 4 mm 3 45 x 2 x 0 57 Dual output Low output ripple and noise Sequenced output start up Monotonic start up Starts into pre biased load Constant switching frequency Positive or negative...

Page 14: ...rsatile 1500V basic isolation Very wide output voltage adjustment trim range Remote sense Monotonic start up Starts into pre biased load Constant switching frequency Active current share Auxiliary sup...

Page 15: ...e 3kV AC isolation input to output Very wide output voltage adjustment trim range Remote sense Monotonic start up Starts into pre biased load Constant switching frequency Active current share Auxiliar...

Page 16: ...building blocks All above bullet features and additionally Isolated remote on off Active current share Auxiliary supply AC DC converters front end converters regulated output Series PFE300S PFE500S P...

Page 17: ...harmonic correction 3kVAC input output isolation EN60555 2 compliant Active current share Enable signal Inverter good signal Constant switching frequency N 1 redundancy AC DC converters front end con...

Page 18: ...99 Fax 1 214 239 3102 E mail support tdkinnoveta com www tdkinnoveta com TDK Corporation of America 475 Half Day Road Lincolnshire IL 60069 2934 Phone 847 699 2299 Fax 847 803 6296 www tdk com TDK Ele...

Reviews: