Wind Tunnel Test Setup Figure

 

Dimensions are 

in millimeters and (inches). 

 
 
Thermal Management: 

 
An important part of the overall system 
design process is thermal management; 
thermal design must be considered at all 
levels to ensure good reliability and lifetime 
of the final system.  Superior thermal design 
and the ability to operate in severe 
application environments are key elements 
of a robust, reliable power module. 
 
A finite amount of heat must be dissipated 
from the power module to the surrounding 
environment.  This heat is transferred by the 
three modes of heat transfer:  convection, 
conduction and radiation.  While all three 
modes of heat transfer are present in every 
application, convection is the dominant mode 
of heat transfer in most applications.  
However, to ensure adequate cooling and 
proper operation, all three modes should be 
considered in a final system configuration. 
 
The open frame design of the power module 
provides an air path to individual 
components.  This air path improves 
convection cooling to the surrounding 
environment, which reduces areas of heat 
concentration and resulting hot spots. 

 

Test Setup:

 The thermal performance data 

of the power module is based upon 
measurements obtained from a wind tunnel 
test with the setup shown in the wind tunnel 
figure.  This thermal test setup replicates the 
typical thermal environments encountered in 
most modern electronic systems with 
distributed power architectures.  The 
electronic equipment in networking, telecom, 
wireless, and advanced computer systems 
operates in similar environments and utilizes 
vertically mounted PCBs or circuit cards in 
cabinet racks. 
 
The power module, as shown in the figure, is 
mounted on a printed circuit board (PCB) 
and is vertically oriented within the wind 
tunnel.  The cross section of the airflow 
passage is rectangular.  The spacing 
between the top of the module and a parallel 
facing PCB is kept at a constant (0.5 in).  
The power module’s orientation with respect  
 

 
 
to the airflow direction can have a significant 
impact on the module’s thermal 
performance. 
 

Thermal Derating:

 For proper application of 

the power module in a given thermal 
environment, output current derating curves 
are provided as a design 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

guideline on the Thermal Performance 
section for the power module of interest.  
The module temperature should be 
measured in the final system configuration to 
ensure proper thermal management of the 
power module.  For thermal performance 
verification, the module temperature should 
be measured at the component indicated in 
the thermal measurement location figure on 
the thermal performance page for the power 
module of interest.  In all conditions, the  
power module should be operated below the 
maximum operating temperature shown on 
the derating curve.  For improved design 
margins and enhanced system reliability, the 
power module may be operated at 
temperatures below the maximum rated 
operating temperature.

 

 
 

AIRFLOW 

Air Velocity and Ambient 
Temperature 
 Measurement Location

 


O

W

 

12.7 
(0.50)

 

Module 
Centerline

 

Air Passage 
Centerline

 

Adjacent PCB 

76  (3.0) 

Summary of Contents for FReta iEB48013A120V

Page 1: ...50Vdc isolation voltage Meets basic insulation spacing requirements Constant switching frequency Industry Standard Footprint Remote on off positive logic Auto recovering input over voltage protection...

Page 2: ...Reta 48V nominal 013 13 5A 017 17A Amps 120 12V 096 9 6V Single 00 Standard Option Table Feature Set Positive Logic On Off Negative Logic On Off 0 110 Pin Length 0 200 Pin Length 0 145 Pin Length 00 X...

Page 3: ...13 Mechanical Specification Dimensions are in mm in Unless otherwise specified tolerances are x x 0 5 0 02 x xx and x xxx 0 25 0 010 Recommended Hole Pattern top view Pin Assignment PIN FUNCTION PIN...

Page 4: ...g estimation Characteristic Min Max Unit Notes Conditions Continuous Input Voltage 0 5 75 Vdc Transient Input Voltage Vdc Isolation Voltage 2250 Vdc Basic insulation Storage Temperature 55 125 C Opera...

Page 5: ...p Delay Time from application of input voltage 10 mS Vo 0 to 0 1 Vo nom on off on Io Io max Tc 25 C Startup Delay Time from on off 10 mS Vo 0 to 0 1 Vo nom Vin Vi nom Io Io max Tc 25 C Output Voltage...

Page 6: ...Io min Vin Vin min 15 5 Vin Vin nom 13 5 Output Current Vin Vin max 1 11 5 A At loads less than Io min the module will operate correctly but the output ripple may increase Output Current Limiting Thr...

Page 7: ...tput voltage 5V div iEB48013A120V 000 Typical startup characteristic from input voltage application at full load 10mS div Upper trace input voltage 20V div lower trace output voltage 5V div iEB48013A1...

Page 8: ...voltage and full load at Ta 25 degrees iEB48013A120V 000 Typical Input Current vs Input Voltage Characteristics iEB48013A120V 000 Typical Output Voltage vs Input Voltage Characteristics 5 7 9 11 13 1...

Page 9: ...scribed in the Thermal Management section Due to the large number of variables in system design TDK Innoveta recommends that the user verify the module s thermal performance in the end application The...

Page 10: ...ost modern electronic systems with distributed power architectures The electronic equipment in networking telecom wireless and advanced computer systems operates in similar environments and utilizes v...

Page 11: ...ay protect themselves by entering a hiccup current limit mode The modules will operate normally once the output current returns to the specified operating range Thermal Protection When the power modul...

Page 12: ...mproper handling or cleaning processes can adversely affect the appearance testability and reliability of the power modules Contact TDK Innoveta technical support for guidance regarding proper handlin...

Page 13: ...The input source is isolated from the ac mains by reinforced insulation 2 The input terminal pins are not accessible 3 One pole of the input and one pole of the output are grounded or both are kept f...

Reviews: