TDK-Lambda ZWS-C Series Instruction Manual Download Page 4

INSTRUCTION MANUAL

ZWS10C • 15C • 30C Series

TDK-Lambda

<Page>

1. Model name identification method

ZWS 10C - 5 /

      Option (*1)

      Rated Output Voltage

                                                                       Series Name
                    

      Output Power type

      Series Name

2. Terminal Explanation

 

L : Input terminal Live line (Fuse in line) (CN1)
N : Input terminal Neutral line (CN1)

: Earth (    ) Terminal (CN2)

Mounting hole (hole diameter : 

φ

3.5mm)  

This hole is electrically connected to terminal of CN2.
The mounting surface of the spacer should be within Max

φ

6.2mm.                                                                                     

Mounting hole (hole diameter : 

φ

3.5mm) 

These holes are used for support the unit.
+ : + Output Terminal (CN51)
– : – Output Terminal (CN51)

4/17

(*1) Blank : Standard type.

/L

: With chassis model.

/A

: With chassis and cover model.

/CO2 : With coating on both sides of                  

                          PCB model.

1
2

3

7

6

5

4

+

-

+

-

ZWS10C/ZWS15C

CN1

3

1

L

N

INPUT

CN2

CN51

OUTPUT

1

2

COMPONENT SIDE

ZWS30C

CN1

3

1

L

N

INPUT

CN2

CN51

OUTPUT

1

2

COMPONENT SIDE

1

2

3

4

5

7

6

5

1

2

3

4

5

7

6

5

Summary of Contents for ZWS-C Series

Page 1: ...product We will not be held responsible after the product has been modified changed or dis assembled Do not use this product under unusual condition such as emission of smoke or abnormal smell and so...

Page 2: ...ction When used in environment with corrosive gas hydrogen sulfide sulfur dioxide etc there is possibility that they might penetrate the product and lead to failure When used in environments where the...

Page 3: ...ure range 5 30 Humidity range 40 60 RH Please keep away from the places where temperature and humidity can change drastically It can cause condensation on the product or deterioration For long term st...

Page 4: ...his hole is electrically connected to terminal of CN2 The mounting surface of the spacer should be within Max 6 2mm Mounting hole hole diameter 3 5mm These holes are used for support the unit Output T...

Page 5: ...2 5A 5 17 Line Filter Rectifier Inrush Current Limit Circuit Filter L N Rectifier Filter Input 85 265VAC V Output V Control Circuit Output Sensing Photo coupler Switching Circuit OVP Circuit OCP Circ...

Page 6: ...int 5V 15V 115 24V 112 ZWS30C 1 OVP point 5V 24V 115 0V Vout 0V Input on Input off Input on Input off OVP point 1 Input Voltage Output Voltage OVP act on OCP act on OCP reset 0V Vout 0V Input on Input...

Page 7: ...nput output connector housing specified by the table below Use recommended crimping tool Connector is not included with this product Refer to the following 7 17 Connector Housing and terminal Pin Term...

Page 8: ...ation the output will not resume To reset OVP remove the input of power supply for a few minutes and then re input In addition the setting value of OVP is fixed and not adjustable Pay attention not to...

Page 9: ...ting more than output load current And maximum reveres voltage must withstand each power supply output voltage 6 7 Isolation Test Isolation resistance between Output terminal is more than 100M at 500V...

Page 10: ...t to 10mA output 20mA The applied voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by hi...

Page 11: ...e the input and cool down to reset over temperature shut down and then re input Load of derating curve indicates output derating values below are based on the maximum output current value at the rated...

Page 12: ...mponent installed to an equipment the equipment must be re evaluated and make sure to meet allowable component temperature Electrolytic capacitor allowable Max temperature 12 17 Mounting A D E F Mount...

Page 13: ...l mounting holes for the unit installation The vibration spec is specified under this mounting condition Recommended torque for mounting screw M3 screw 0 59N m 6 0 kgf cm Mounting Holes size Allowable...

Page 14: ...l of the equipment If not connected the conducted noise radiation noise and output noise may increase 4 For Installation in Class II end equipment terminal Earth is unnecessary to be connected to Prot...

Page 15: ...commended torque for mounting screw M3 screw 0 59N m 6 0 kgf cm Refer to the A type and L type outline drawings for the detailed dimensions A type L type Mounting Holes size A 2 M3 tapped embossed and...

Page 16: ...current value at input turn on Do not select the fuse according to actual input current rms values ZWS10C 1 0A ZWS15C 1 0A ZWS30C 2 5A 10 Before concluding that the unit is at fault 1 Check if the ra...