QM range App Note, document number 260283, rev 15
Page 14 of 48
SA Modules
The output voltage is fixed and cannot be adjusted.
The remote sense (on 5V modules only) provides compensation for a
maximum total load cable drop of 0.5V for the output. See the Remote Sense
section in the POWER SUPPLY OPERATION chapter for connection advice.
Connector pin-out for signals
(on 5V modules only)
Pin
Function
1
No connection
2
3
4
5
6
7
Remote Sense +
8
Remote Sense -
9
No connection
10
Molex mating connectors and pins
(Contact Molex for other pin alternatives)
Description
Molex part
number
TDK-Lambda
part number
10 way Milli-Grid with locking ramp
51110-1060
12934
Crimp terminal, gold flash, female, supplied on a reel
50394-8051
12935
Crimp terminal, gold flash, female, supplied in a bag
50394-8400
Crimp terminal, tin plated, female, supplied on a reel
51087-8101