TDK-Lambda LC1202 Instruction Manual Download Page 3

83-000-005 Rev F

ONE YEAR WARRANTY

TDK-Lambda Americas, Inc. (405 Essex Road, Neptune, N.J. 07753), warrants that the unit is free from defects in
material or workmanship for a period of ONE YEAR from the date of initial shipment. TDK-Lambda Americas Inc. will
service and, at its option, repair or replace parts which prove to be defective. This will be done free of charge during
the stated warranty period. This warranty excludes defects resulting from misuse, unauthorized modification,
operation outside the environmental or safety specifications of the power supply, or improper site preparation or
maintenance. The customer shall contact TDK-Lambda Americas Inc., for warranty service or repair as described in
the RETURNING EQUIPMENT section. The customer shall prepay shipping charges. If the unit is covered under the
foregoing warranty, then TDK-Lambda Americas Inc. shall pay the return shipping charges.

The “WARRANTY”, “CLAIM FOR DAMAGE IN SHIPMENT”, and “RETURNING EQUIPMENT” information applies to
equipment purchased directly from TDK-Lambda Americas Inc. End users receiving equipment from a third party
should consult the appropriate service organization for assistance with these issues.

THIS LIMITED WARRANTY IS IN LIEU OF, AND TDK-LAMBDA AMERICAS INC. DISCLAIMS AND EXCLUDES,
ALL OTHER WARRANTIES, STATUTORY, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OF CONFORMITY TO
MODELS OR SAMPLES.

CERTIFICATION

All test and measuring equipment used by TDK-Lambda Americas Inc. for Final Acceptance Testing are traceable to
primary standards certified by the National Institute of Standards and Technology.

LETHAL VOLTAGES PRESENT!

All power supplies contain hazardous voltage and energy. The power supply must only be operated by qualified
personnel who have read this operator’s manual and are familiar with the operation, hazards and application of the
power supply. Proper care and judgment must always be observed.

1.

Before connecting input AC power, ensure all covers are in place and securely fastened. Ensure the required
safety ground to chassis is installed and sufficient cooling is supplied.

2.

Proper grounding from the input AC power is required to reduce the risk of electric shock, and to comply with
safety agency and code requirements.

3.

Use extreme caution when connecting input AC power. Only apply the input voltage specified on the rating label.

4.

Use extreme caution when connecting any high voltage cables. Never handle any output cables when the power
supply is operating.

5.

After a power supply is switched OFF, its output section will retain a charge which may be lethal. Allow sufficient
time for self-discharge before handling anything connected to the output. The discharge time specified in the
Safety Notes does

NOT

include extra time required to discharge the energy stored in the user’s load.

6.

When user serviceable fuses are present, always replace fuses with the same type and Volt/Amp rating.

7.

Never attempt to operate the power supply in any manner not described in this manual.

8.

Never remove DANGER or WARNING labels from the power supply. Replace lost or damaged labels
immediately. Contact TDK-Lambda Americas Customer Service for replacement labels.

9.

The power supply may be serviced only by TDK-Lambda Americas Inc. factory qualified service personnel.
Breaking the warranty seal will void the warranty. Prior to opening the power supply, contact TDK-Lambda
Americas Inc. Customer Service for a written Service Waiver and a replacement warranty seal.

Summary of Contents for LC1202

Page 1: ...94001 Rev J INSTRUCTION MANUAL FOR LC1202 HIGH VOLTAGE POWER SUPPLY 83494001 Revision J TDK Lambda Americas Inc 405 ESSEX ROAD NEPTUNE NJ 07753 TEL 732 795 4100 FAX 732 922 9334 WEB www us tdk lambda...

Page 2: ...as defined by TDK Lambda Americas Inc for the products described by this manual is stated as follows The Power Supplies described by this manual are intended for use in a protected industrial environm...

Page 3: ...AL VOLTAGES PRESENT All power supplies contain hazardous voltage and energy The power supply must only be operated by qualified personnel who have read this operator s manual and are familiar with the...

Page 4: ...ive 93 68 EEC European Community Conformity Assessment Product Mark IEC 348 Attention consult Accompanying documents IEC 60417 1 5036 Dangerous voltage IEC 60417 1 5019 Protective earth e g power line...

Page 5: ...ipment to the factory the following steps shall be taken 1 Notify TDK Lambda Americas Inc at 732 795 4100 or follow the instructions at US TDK Lambda com HP service htm Give a full description of the...

Page 6: ...4 POLARITY 2 2 5 HV INSULATING MEDIUM 2 2 6 INPUT CONNECTIONS 2 2 7 INPUT REQUIREMENTS 2 2 8 POWER FACTOR 2 2 9 EFFICIENCY 2 2 10 STORED ENERGY 2 2 11 STABILITY 3 2 12 PULSE REPEATABILITY 3 2 13 PHYSI...

Page 7: ...NE 8 3 6 2 OUTPUT GROUND CONNECTION 8 4 OPERATION 10 4 1 L S OEM MODELS 10 4 2 REAR PANEL 11 4 3 FRONT PANEL CONTROL L MODEL ONLY 12 4 3 1 POWER SWITCH 12 4 3 2 CONTROL SWITCH 12 4 3 3 HV ON SWITCH 12...

Page 8: ...2 7 2 1 CHANGE SELECTOR BOARD 22 7 2 2 CHANGE FUSE 22 7 2 3 SELECTOR SWITCHES ON AUX POWER BOARD 23 7 2 4 CORRECTING THE INPUT LABEL 23 List of Figures Description Page Figure 1 LC1202 Block Diagram 1...

Page 9: ...t regulation of the output voltage and automatically compensates for line load and temp variations The latest development resonant inverter topology which improves pulse to pulse re peatability by red...

Page 10: ...1 35A 30KV 0 9A 2 3 1 LINEARITY To within 1 of full scale 2 3 2 ACCURACY To within 1 of rated output 2 4 POLARITY Available as fixed positive or negative 2 5 HV INSULATING MEDIUM Silicone oil 2 6 INPU...

Page 11: ...7 COOLING WATER 2GPM 7 6 liters min max supply temp 35 C All water paths are at ground potential and are copper or brass An analog temp signal 0 10VDC is provided for a heat sink temp of 10 60 3 C at...

Page 12: ...500Hz 0 015g2 Hz Duration 1 hour 2 24 SHOCK 25Gpk half sinewave 11ms 2 25 FRONT PANEL DISPLAY Voltage and current 3 character indicators 10 segment voltage and current trend graphs HV ON push button...

Page 13: ...83494001 Rev H Page 5 of 27 Figure 2 Mechanical Details...

Page 14: ...ling water supply with a minimum 2GPM 7 6 l m flow and a maximum inlet temp of 35 C The water connection is at the rear of the supply The connection is SWAGELOK 12mm The water flow direction must be a...

Page 15: ...sert the connector end of the HV cable and tighten the locking nut only hand tight When operating above 20kV or 200 Hz rep rate it is recommended that a silicone grease such as Dow Corning DC 4 be use...

Page 16: ...Some peak current will flow out of the power supply during discharge and return through the HV return and system chassis This current comes from voltage reversal in under damped systems and from norm...

Page 17: ...Ground Connection This product is NOT protected against external load voltage reversal events Load voltage reversal may result in damage to the unit which is not covered by the standard product warra...

Page 18: ...ed which is controlled by the front panel power switch The model LC1202L can be operated as a master unit in parallel with several model LC1202S slave units for increased output power Refer to Section...

Page 19: ...ONTROL KEY SWITCH on the front panel is in the REMOTE position The INTERLOCK terminal block internal 24 DC can be con nected to system interlocks to disable the power supply when opened Jumper the two...

Page 20: ...es the power supply regardless of other com mands 4 3 3 HV ON SWITCH Turns on the high voltage output to the level set by the HV adjust knob Also used with HV OFF to reset latched fault conditions ove...

Page 21: ...k charging voltage Impedance 1k If the 5V option is installed the voltage level is 0 5V 10 HV ON LED Open collector through 100 Low impedance when HV output is enabled See Note 1 12 GROUND Control cir...

Page 22: ...that are common to the remote control interface indicator signals A pullup resistor is not required to sense the remote interface voltage on these signals The user should expect the Active Logic leve...

Page 23: ...83494001 Rev H Page 15 of 27 Figure 10 Suggested Interface...

Page 24: ...1202L Front Panel Control 1 Turn HV ADJUST knob fully counterclockwise 2 Turn POWER switch to ON 3 Turn CONTROL key switch to LOCAL 4 Push HV ON switch 5 Verify the HV output is at approx zero volts 6...

Page 25: ...00 J sec VOLTAGE TIME Tc Tp 5 2 VOLTAGE REVERSAL SEE ONLINE APP NOTE 517 FOR MORE DETAILS When the capacitor or PFN is discharged a high peak current may flow out of the power supply as a result of vo...

Page 26: ...e cases it is necessary to wrap the cables several times through large ferrite cores at the rear panel of each unit 5 4 MEASURING HIGH VOLTAGES A sample of the output voltage is available in the REMOT...

Page 27: ...AS A DC POWER SUPPLY The LC1202 can provide a regulated voltage to a DC load such as an electron beam The output current will be preset at the factory in order to limit the average output power to 12...

Page 28: ...assembly hermetically sealed Opening the assembly may compromise performance 6 4 TROUBLESHOOTING First check for obvious trouble such as input power output connections control connec tions and signal...

Page 29: ...83494001 Rev H Page 21 of 27 Check the V PROGRAM input at U1 12 Check the clock at Drain Q4 Check the transistor gate drives at Q4 Q5 Q8 Q10...

Page 30: ...upply is disconnected from the line and load and all caps must be discharged Take the cover off On the inverter board Figure 11 discharge the bus capacitor by shorting SWGC1 SWGC2 and SWGC3 SWGC4 with...

Page 31: ...There are 3 selector slide switches on the Aux Board which have to be correctly selected For 208VAC line operation the position of the slide switches should be so that 110VAC is visible For 400V line...

Page 32: ...83494001 Rev H Page 24 of 27 Figure 11 Power Supply Top View...

Page 33: ...83494001 Rev H Page 25 of 27 Figure 12 Power Supply Bottom View...

Page 34: ...83494001 Rev H Page 26 of 27 Figure 13 Aux Board...

Page 35: ...83494001 Rev H Page 27 of 27 Figure 14 Fuse Assembly...

Page 36: ......

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ......

Page 41: ......

Page 42: ......

Page 43: ......

Page 44: ......

Page 45: ......

Page 46: ...GS 8 16 2017 BHuhn 8 16 17 A Hague 8 16 17...

Page 47: ......

Page 48: ......

Page 49: ......

Page 50: ......

Reviews: