HWS 30A-150A/ME Series   

Instruction Manual 

 

 

 

 

 

 

BEFORE USING THE POWER SUPPLY UNIT

 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before   
using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. 

 
 

 

DANGER

 

Never use this product in locations where flammable gas or ignitable substances are present. There are risks of igniting these   
substances and exploding by an arcing. 

 
 

 

WARNING

 

 

Do not touch this product or its internal components while circuit is live, or shortly after shutdown. There may be high voltage or   
high temperature present and you may receive an electric shock or burn. 

 

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. 

 

Do not make unauthorized changes to this product, otherwise you may receive an electric shock and void your warranty. 

 

Do not drop or insert anything into this product. It might cause a failure, fire and electric shock. 

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. 

    It might lead to fire and electric shock. In such cases, please contact us. Do not attempt repair by yourself, as it is dangerous for the   

user. 

 

Do not operate these products in the presence of condensation. It might lead fire and electric shock. 

 
 

 

CAUTION

 

 

This power supply is designed and manufactured for use within an end product such that it is accessible to   

SERVICE ENGINEERS only. 

 

Confirm connections to input/output terminals and signal terminal are correct as indicated in the instruction manual   

before switching on. 

 

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications,   

otherwise the product will be damaged. 

 

Do not operate and store this product in an environment where condensation might occur. In such case, waterproof treatment is   

necessary. 

 

Do not use this product in environment with a strong electromagnetic field, corrosive gas or conductive substances. 

 

For applications, which require very high reliability (Nuclear related equipment, medical equipment, traffic control equipment, etc.),   

it is necessary to provide a fail-safe mechanism in the end equipment. 

 

Do not inject abnormal voltages into the output or signal of this product. The injection of reverse voltage or over voltage   

exceeding nominal output voltage into the output or signal terminals might cause damage to internal components. 

 

Never operate the product under over current or short-circuit conditions, or outside its specified Input Voltage Range.   

Insulation failure, smoking, burning or other damage may occur. 

 

This product contains a printed circuit board utilizing surface mounted devices. 

PCB stress such as bending, twisting etc. could cause damage. Therefore, please handle with care. 

 

This power supply has possibility that hazardous voltage may occur in output terminal depending on failure mode. 

The output of these products must be protected in the end use equipment to maintain SELV. 

 

The information in this document is subject to change without prior notice. Please refer to the latest version of the data sheet, etc.,   

for the most up-to date specifications of the product. 

 

No part of this document may be copied or reproduced in any form without prior written consent of TDK-Lambda. 

 

 

Note : CE MARKING 

CE Marking when applied to a product covered by this handbook indicates compliance with the low voltage directive 
(2006/95/EC) in that it complies with EN60950-1.

 

 

 
 

 

 
 

TDK-Lambda 

HWS 30

A-150A/ME

 Series 

INSTRUCTION MANUAL

 

Summary of Contents for HWS ME Series

Page 1: ...Output power ambient temperature and ambient humidity should be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensa...

Page 2: ...g parameters Material Group IIIb Pollution Degree 2 Overvoltage Category II Class I earthed Indoor use as part of an overall equipment such that the product is accessible to service engineers only EMC...

Page 3: ...xygen or with nitrous oxide No 3 These products are classed as ordinary equipment according to IEC EN ES CSA60601 1 and are NOT protected against the ingress of water 4 The output circuit has not eval...

Page 4: ...stment trimmer Output monitoring indicator Green LED All screws size is M3 5 HWS100A ME HWS150A ME V Output terminal 30A max terminal V Output terminal 30A max terminal FG Frame Ground L Input termina...

Page 5: ...nt of noise sensitivity HWS30A ME HWS50A ME HWS100A ME HWS150A ME Basic connection Local sensing Connect S terminal to V terminal and S terminal to V terminal with the attached short pieces Short piec...

Page 6: ...Power thermistor method so that higher current will flow at higher ambient temperature or re input condition Please select input switch and fuse carefully with the high temperature and re input the p...

Page 7: ...e load terminal 2 Between S terminal and V terminal 3 Between S terminal and V terminal If remote sensing terminals are opened the output will rise and OVP may be triggered 4 7 Output Ripple Noise The...

Page 8: ...he power supply output voltage higher by the amount of forward voltage drop VF of the diode 2 Please adjust the output voltage of each power supply to be the same 3 Please use within the specification...

Page 9: ...o frame ground Some of the withstand voltage tester may generate high voltage at the matching with monolithic ceramic capacitor and may cause the unit damage So please check the waveform of test volta...

Page 10: ...of mounting screws is 6mm 4 Recommended torque for mounting screw HWS30A ME HWS150A ME M3 screw 0 49 N m 5 0 kgf cm 5 2 Output Derating according to the Mounting Directions Recommend standard mounting...

Page 11: ...WS30A ME HWS50A ME HWS100A ME Ta Load Mounting A B C D 10 50 100 60 60 70 40 Ta Load Mounting A Mounting B D Mounting C 10 45 100 100 100 50 100 100 86 60 70 65 58 70 40 30 30 Ta Load Mounting A Mount...

Page 12: ...minal M3 5 Screws 1 0N m 10 2kgf cm 1 6N m 16 3kgf cm 6 8mm 0 8mm 2 piece HWS100A ME AWG12 22 Output terminal M3 5 Screws 1 0N m 10 2kgf cm 1 6N m 16 3kgf cm 8 1mm 1 0mm 1 piece 0 8mm 2 piece AWG14 22...

Page 13: ...ME 3 15A HWS150A ME 5A 9 Before concluding that the unit is at fault Before concluding that the unit is at fault make the following checks 1 Check if the rated input voltage is connected 2 Check if t...

Reviews: