6. Mounting Directions
6-1. Output Derating according to the Mounting Directions
Recommended standard mounting is Method ( A ). Method ( B ) is also possible.
Refer to the Derating below.
(A) Standard Mounting (B)
6-2. Output Derating
For /L and /F option, the system is forced air cooling with external airflow of at least 15cfm and air blowing out from the
opposite side of the input/output connectors.
70
50
Airflow
(
≥
15 cfm)
OUTPUT DERATING CURVE
0
20
40
60
80
100
120
-25
0
25
50
75
100
Ta (
o
C)
L
O
AD (
%
)
MOUNTING
A,B
70
50