TDK-Lambda GENESYS GEN 5kW Series User Manual Download Page 64

55

7.7.5 Output control commands-cont

55

#

Command

Description

Sets the Foldback protection to ON or OFF.
FLD 1 (or FOLD ON) - Arms the Foldback protection.
FLD 0 (or FOLD OFF)- Cancels the Foldback protection.
When the Foldback protection has been activated, OUT 1 command will release the

protection and re-arm it, while FLD 0 will cancel the protection.

Returns the Foldback protection status string:

“ON”- Foldback is armed,

“OFF”- Foldback is canceled.

Add (nn x 0.1) seconds to the Fold Back Delay. This delay is in addition to the standard

delay. The range of nn is 0 to 255. The value is stored in eprom at AC power down and

recovered at AC power up.

Supply returns the value of the added Fold Back Delay.

Reset the added Fold Back Delay to zero.

Returns the output On/Off status string.
ON- output on.

OFF- output off.

Display Voltage and Current data. Data will be returned as a string of ASCII characters. A

comma will separate the different fields. The fields, in order, are: Measured Voltage,

Programmed Voltage, Measured Current, Programmed Current, Over Voltage Set point

and Under Voltage Set Point.
Example: 5.9999, 6.0000, 010.02, 010.00, 7.500, 0.000

10

FLD n

11

12

13

14

FLD?

FBD nn

FBD?

FBDRST

9

8

OUT?

Sets the OVP level. The OVP setting range is given in Table 7-5. The number of characters

after OVP is up to 12.

The minimum setting level is approx. 105% of the set output voltage, or the value in Table

7-6, whichever is higher. The maximum setting level is shown in Table 5-1. Attempting to

program the OVP below this level will result in execution error response (”E04”). The OVP

setting stays unchanged.

15

OVP n

Returns the power supply operation mode. When the power supply is On (OUT 1) it will

return “CV” or “CC”. When the power supply is OFF (OUT 0) it will return “OFF”.

Returns the Master/Slave setting.

Master: n = 1, 2, 3, or 4

Slave: n = 0

Saves present settings. The settings are the same as power-down last settings.
These settings are erased when the supply power is switched off and the new “last settings”

are saved.

Sets Under Voltage Limit. Value of “n” may be equal to PV setting, but returns “E06” if

higher. Refer to Table 7-6 for UVL programming range.

Sets OVP level to the maximum level. Refer to Table 7-5.

Returns the setting “n” where “n” is the exact string in the user’s “UVL n”. When in Local

mode, returns the last setting from the front panel in a 4 digit string.

Returns the setting “n” where “n” is the exact string in the user’s “OVP n”. When in Local

mode, returns the last setting from the front panel in a 4 digit string.

Returns the string auto-restart mode status.

Recalls last settings. Settings are from the last power-down or from the last “SAV”

command.

16

OVP?

17

OVM

18

UVL n

19

UVL?

21

AST?

22

SAV

23

RCL

24

25

MODE?

MS?

Sets the auto-restart mode to ON or OFF.

AST 1 (or AST ON)- Auto restart on.

AST 0 (or AST OFF)- Auto restart off.

20

AST n

Reads the actual output current. Returns 5 digits string.

Example: 200A supply sends 000.50, 110.12, 200.00, etc...

Turns the output to ON or OFF. Recover from Safe-Start, OVP or FLD fault.

OUT 1 (or OUT ON)-Turn On.

6

MC?

(See Note 2)

7

OUT n

DVC?

Summary of Contents for GENESYS GEN 5kW Series

Page 1: ...le DC Power Supplies 5kW in 2U Built in RS 232 RS 485 Interface Advanced Parallel Operation Optional Interface N A L t n a i l p m o C IEEE488 2 SCPI GPIB Multi Drop Isolated Analog Programming www he...

Page 2: ...8 5 IA657 04 01 Rev E USER MANUAL This Manual Covers Models GEN8 600 GEN10 500 GEN16 310 GEN20 250 GEN30 170 GEN40 125 GEN60 85 GEN80 65 GEN100 50 GEN150 34 GEN200 25 GEN300 17 GEN400 13 GEN500 10 GE...

Page 3: ...us Substances Notes Concentration Values of Toxic and Hazardous Substances Elements wt Subpart Name This information sheet was prepared based on People s Republic of China Management Methods for Contr...

Page 4: ...5 A1 1998 A2 2001 ESD AD 8KV CD 4KV EN 61000 4 3 2006 Radiated Immunity 3V m EN 61000 4 4 2004 EFT B Power leads 2KV Signal leads 0 5KV EN 61000 4 5 2006 Conductive Surges Common mode 2KV Differential...

Page 5: ...This page intentionaly left blank...

Page 6: ...ACTERISTICS 2 13 OUTLINE DRAWINGS 3 1 GENERAL 3 2 PREPARATION FOR USE 3 3 INITIAL INSPECTION 3 4 RACK MOUNTING 3 4 1 To install the power supply in a rack 3 4 2 Rack mount slides 3 5 LOCATION MOUNTING...

Page 7: ...5 3 2 Activated OVP protection indications 5 3 3 Resetting the OVP circuit 5 4 UNDER VOLTAGE LIMIT UVL 5 4 1 Setting the UVL level 5 5 FOLDBACK PROTECTION 5 5 1 Setting the Foldback protection 5 5 2...

Page 8: ...7 3 Initialization control commands 7 7 4 ID control commands 7 7 5 Output control commands 7 7 6 Global output commands 7 7 7 Status control commands 7 8 STATUS ERROR AND SRQ REGISTERS 7 8 1 General...

Page 9: ...This page intentionaly left blank...

Page 10: ...occurring as a result ofthe buyer s circuitry or the buyer s supplied products No other warranty is expressed or implied WARRANTY SERVICE This product must be returned to an authorized TDK Lambda Ltd...

Page 11: ...racombe Devon EX34 8ES UK TM NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to prov...

Page 12: ...use a potential shock hazard that might cause personal injury There is a potential shock hazard at the RS232 485 and the IEEE ports when using power supplies with rated or combined voltage greater tha...

Page 13: ...Terminal Off Supply On Supply Direct Current DC Alternative Current AC Three PhaseAlternating Current Standby Supply The WARNING sign denotes a hazard An attention to a procedure is called Not followi...

Page 14: ...5...

Page 15: ...6...

Page 16: ...ow the user to set the output parameters the protection levels Over Voltage protection Under Voltage limit and Foldback and preview the settings The rear panel includes the necessary connectors to con...

Page 17: ...pply The output voltage and the current limit can be programmed by analog voltage or by resistor and can be monitored by analog voltage The power supply output can be remotely set to On or Off and ana...

Page 18: ...45 type plugs 8 contacts P N GEN RJ45 AC Input plug connector Phoenix Contact PC 6 4 STF 10 16 Output terminal shield Plastic legs for bench mounting AC cables are not provided with the power supply...

Page 19: ...100 80 600 400 21 10 5 22 11 22 11 22 12 22 11 22 11 22 11 22 11 22 11 22 11 22 11 22 11 22 11 22 11 22 11 3 Power Factor Typ 4 Efficiency 4 5 Inrush current 5 2 Maximum Input current at 100 load 1 In...

Page 20: ...FOLDBACK REMOTE RS232 RS485 IEEE OUTPUT ON FRONT PANEL LOCK 1 Control functions 2 Display 3 Indications 2 9 ENVIRONMENTAL CONDITIONS 1 Operating temperature 2 Storage temperature 3 Operating humidity...

Page 21: ...hange equal to the unit voltage rating constant input voltage 12 For 8V 16V models the ripple is measured at 2V to rated output voltage and rated output current For other models the ripple is measured...

Page 22: ...nting holes 10 32 marked A GENERAL DEVICES P N CC3001 00 S160 or equivalent 6 Bus Bar enclosure for 60V to 600V 7 Mounting holes for 19 rack Use M6x16 screws to fix the unit to the rack Note 2 Bus Bar...

Page 23: ...e are not scratched or cracked Keep all packing material until the inspection has been completed If damage is detected file a claim with carrier immediately and notify the Lambda sales or service faci...

Page 24: ...15...

Page 25: ...base while holding the cable in place Now the cable is securely fastened inside the strain relief Refer to Fig 3 2 WARNING AC input cord is not provided with power supply WARNING Some components insi...

Page 26: ...for the location of the controls indicated in the procedure 1 Ensure that the power supply is configured to the default setting AC On Off switch at Off position Dip switch All positions at Down Off p...

Page 27: ...play Ensure that the front panel CURRENTLED is on 6 Turn off the front panelAC power switch 7 Remove the shunt from the power supply output terminals Refer to Section 5 3 for explanation of the OVPfun...

Page 28: ...ort Baud Rate 2 Using The CURRENT adjust encoder check that the Baud Rate can be set to 1200 2400 4800 9600 and 19200 3 8 8 Address Setting 3 8 9 Baud Rate Setting 3 9 CONNECTING THE LOAD 19 Shorting...

Page 29: ...20...

Page 30: ...may be harmful to the power supply Adiode should be connected across the output The diode voltage and current rating should be greater than the power supply maximum output voltage and current rating...

Page 31: ...laces Flat washer 2 places Screws tightening torque 290 310 Lb inch Output Load Wires No Conductor Pretreatment Phoenix Contact clamping parts are designed so that all kinds of copper conductors can b...

Page 32: ...own the shutter to secure load wires in place and tighten screws B Fig 3 10 Enclosure assembly Load wires Negative Output Return Positive output Shutters Enclosure bottom cover Enclosure top cover B A...

Page 33: ...o minimize noise pick up If shielded wires are used the shield should be connected to the ground at one point either at the power supply chassis or the load ground The optimal point for the shield gro...

Page 34: ...ded wires Each load should be separately connected to the remote distribution terminals see Fig 3 14 If remote sensing is required the sensing wires should be connected to the distribution terminals o...

Page 35: ...an the maximum output voltage of the power supply Ensure that the connections at the load end are shielded to prevent accidental contact with hazardous voltages 3 10 2 Local sensing The power supply i...

Page 36: ...that the J2 mating connector is plugged securely into the rear panel sense connector J2 4 Turn On the power supply 1 If the power supply is operating in remote sense and either the positive or negativ...

Page 37: ...ion 4 3 Rear panel controls and connectors See Fig 4 1 to review the controls indicators and meters located on the power supply front panel TM 28 1 Number Control Indicator Description Section High re...

Page 38: ...display shows OUP Press again to set the UVLusing VOLTAGE encoder the current display shows UUL Main function Auxiliary function Go to local Press REM LOC to put the unit into Local REM LOC button is...

Page 39: ...er supply rear panel Refer to Table 4 2 for explanations about the rear panel connections and controls Fig 4 2 Rear panel connections and controls 1 Number Item Description Section AC input connector...

Page 40: ...e or RS232 485 mode when IEEE option is installed Number Item Description Section 4 5 Connector for making remote sensing connections to the load for regulation of the load voltage and compensation of...

Page 41: ...f logic select RS232 485 select Output Voltage Resistive programming Output Current Limit Resistive programming Enable Disable control Up Output Voltage Programmed by remote analog External Voltage or...

Page 42: ...nt Manual Pistol grip tool Handle AMP P N 58074 1 Head AMP P N 58063 2 Before making any connection turn the AC On Off switch to the Off position and wait until the front panel display has turned Off...

Page 43: ...34...

Page 44: ...t voltage When the output is disabled press the PREV button and then rotate the VOLTAGE encoder knob The VOLTAGE meter will show the programmed output voltage for 5 seconds after the adjustment has be...

Page 45: ...ncoder knob to adjust the OVP level The display will show OUP and the setting value for 5 seconds after the adjustment has been completed and then will return to it s previous state The minimum settin...

Page 46: ...cancel the Foldback protection The power supply output will be disabled and the VOLTAGE display will show OFF Press the OUTbutton to enable the power supply output 3 Turn the power supply output Off...

Page 47: ...open collector output with a 30V parallel zener at J1 13 referenced to the COM potential at J1 12 connected internally to the negative sense potential When the power supply operates in Constant Voltag...

Page 48: ...lay shows O7P and the ALARM LED blinks Resetting the OTP circuit can be automatic non latched or manual latched depending on the Safe orAutomatic restart mode In Safe start mode the power supply stays...

Page 49: ...one of the units shuts down Each diode should be rated to at least the power supply rated output voltage and output current Refer to Fig 5 1 and 5 2 for series operation with local and remote sensing...

Page 50: ...485 4 Programming via the Serial Communication port RS232 RS485 5 14 2 Series connection for positive and negative output voltage In this mode two units are configured as a positive and negative outpu...

Page 51: ...y the number of parallel units During operation the master unit operates in CV mode regulating the load voltage at the programmed output voltage Connect the sensing circuit to local or remote sensing...

Page 52: ...atically set the following Output voltage to approximate 102 of rated output voltage Programmed Current to zero UVL to zero volts OVP to its maximum value c The Master and Slave modes are stored in th...

Page 53: ...SO SO IF_COM IF_COM IF_COM 5 17 FRONT PANEL LOCKING The front panel controls can be locked to protect from accidental power supply parameter change Press and hold PREV button to toggle between Locked...

Page 54: ...output voltage and current limit can be programmed via the front panel VOLTAGE and CURRENT encoders or via the RS232 485 port In Remote Analog mode the output voltage and current limit can be program...

Page 55: ...and SW1 2 to its UP position for Output Current limit external programming 3 Set SW1 position 3 to select programming voltage range according to Table 6 3 4 Ensure that SW1 positions 7 and 8 are at th...

Page 56: ...ng resistors to the mating plug of J1 as shown in Fig 6 2 7 Set the programming resistors to the desired resistance and turn the power supply ON Adjust the resistors to change the power supply output...

Page 57: ...monitor Iout monitor Vout monitor Iout monitor Signal J1 11 J1 24 J1 11 J1 24 J1 12 J1 12 0 5V 0 10V Down Up Range SW1 4 Return J1 connection Table 6 5 Monitoring signals setting FCC requirements for...

Page 58: ...ess REM LOC button to put the unit into Local mode 2 Press and hold for approximately 3sec the REM LOC button The VOLTAGE display will indicate the communication port address 3 Using the VOLTAGE adjus...

Page 59: ...t to set the status registers and read them while the unit is in Local mode If the Enable registers are set refer to section 7 8 the power supply will transmit SRQ s while in Local Front panel control...

Page 60: ...51...

Page 61: ...rity bit The Address is sent separately from the command It is recommended to add a 100 msec software delay between query or sent command to next unit addressing Refer to section 7 7 3 for details The...

Page 62: ...sets a numeric value the value may be up to 12 characters long 4 Carriage Return If the CR character ASCII 13 is received by itself the power supply will respond with OK and CR The Genesys 5000W serie...

Page 63: ...4 7 7 5 Output control commands 7 7 4 ID control commands Command Description Returns the power supply model identification as an string Returns the software version as an ASCII string Returns the uni...

Page 64: ...setting level is shown in Table 5 1 Attempting to program the OVP below this level will result in execution error response E04 The OVP setting stays unchanged 15 OVP n Returns the power supply operati...

Page 65: ...P Max UVL 0 The conditional register FLT and STAT are updated Other registers are not changed Non Latching faults FB OVP SO are cleared OUT fault stays Sets the output voltage value in volts The range...

Page 66: ...d current PC programmed set current SR status register 2 digit hex FR fault register 2 digit hex Example response MV 45 201 PV 45 MC 4 3257 PC 10 SR 30 FR 00 Reads Fault Conditional Register Return 2...

Page 67: ...command or query received One SRQ when SEVE goes from all zeroes to any bit set Setting more SEVE bits does not cause more SRQs Positive Logic 0 No Event 1 Event Occured 7 8 STATUS ERROR AND SRQ REGIS...

Page 68: ...utdown has occurred The supply output is turned On by front panel button or OUT 1 command The supply output is turned On by front panel button or OUT 1 command The supply output is turned On by front...

Page 69: ...SO OFF ENA Bit Set condition Bit reset condition User command FENA nn where nn is hexadecimal User command FENA nn where nn is hexadecimal if nn 00 no fault SRQs will be generated Table 7 10 Fault Ev...

Page 70: ...E command to read the register CLS and power up also clear the Status Event Register The Fault Event Register is not cleared by RST BIT Status name Status symbol Bit Set condition Bit reset condition...

Page 71: ...ends with line feed On some PC systems pressing the number keypad Enter will distort displayed messages Use the alphabetic Enter instead Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow...

Page 72: ...tage programming temperature coefficient Output current programming temperature coefficient Input impedance Absolute maximum voltage Max voltage between program inputs and supply outputs Output voltag...

Page 73: ...oltage programming input Output current programming input 2 IPROG_ISO 3 Ground for programming signals Ground for programming signals Output voltage monitoring output Output current monitoring output...

Page 74: ...f the voltage source 8 Set the programming sources to the desired levels and turn the power supply ON Perform the following procedure to configure the power supply 1 Turn the power supplyAC power swit...

Page 75: ...ition for Output Current limit external programming 4 Set SW1 position 3 to select the programming voltage range Down 0 5V Up 0 10V 5 Set SW1 position 4 to select the monitoring range Down 0 5V Up 0 1...

Page 76: ...e made only by the manufacturer or by authorized service facilities no parts replacement information is provided in the manual In case of failure unusual or erratic operation of the unit contact a Lam...

Page 77: ...is installed adjacent to heat generating equipment Check Foldback setting and load current Connect the sense wires according to User s manual instructions Turn Off the AC power and wait until the dis...

Page 78: ...rte Pressluft um das Ger t von Staub zu befreien 9 4 Justagen und Kalibrierung Interne Justage oder Kalibrierung ist nicht n tig Es gibt keinen Grund die Stromversorgung zu ffnen 9 5 Bauteilewechsel u...

Page 79: ...rbeitet das Ger t im Konstantspannungs Modus Strombegrenzung und Spannungseinstellungen pr fen 5 2 Die Ausgangsspannung hat eine hohe Restwelligkeit Werden die Sense Anschl sse benutzt Ist der Spannun...

Page 80: ...sen so muss das Ger t zur Reparatur gegeben werden Sicherungen d rfen ausschlie lich von daf r geschultem technischen Personal ausgewechselt werden In Tabelle 9 2 sind die Sicherungswerte aufgelistet...

Page 81: ...ing power supplies line feed local operation local sensing lock front panel maintenance otp outline over voltage parallel operation parity ps_ok preview rack mounting rear panel remote sensing remote...

Page 82: ...Nilai Industrial Estate 71800 Nilai Negeri Sembilan Malaysia Tel 60 6 799 1130 Fax 60 6 799 3277 www tdk lambda com my NORTH AMERICA TDK Lambda Americas Inc 405 Essex Rd Neptune NJ 07753 Tel 1 732 922...

Reviews: