background image

 

 

20 

Image 

Component 

Quantity 

 

Paralleling Cable  

 

Fixing Bracket 

 

M3 x 8 SEMS Screw, Nickel Plated 

Output Bracket G+15KW 

 

M3 x 10 SEMS Screw, Nickel Plated 

Output Bracket 

 

M3 x 6G Flat Head Screw, Nickel Plated 

 

Output Plug 

 

 

 

Summary of Contents for G/P-3U-10V

Page 1: ...Series Programmable DC Power Supplies G1 7 5kW in 1U 0 600V 0 500A PARALLEL KIT INSTRUCTION MANUAL The manual covers kit options G P 3U 10V G P 3U 20 40V G P 3U 60 100V G P 3U 150 600V...

Page 2: ...assembly When using a paralleling kit with a protective bracket it must be correctly assembled as described further in this document 1 4 Assembly Instructions The supplied kit is used for standard an...

Page 3: ...3 Image Component Quantity M3 x 4C Flat Head Screw Nickel Plated 8 Paralleling Cable 2 Output Cover 1 Bus Bar Insulator 2 M3 x 8 SEMS Screw Nickel Plated 6...

Page 4: ...ch output short plates one on each triple of terminals using eight flat head screws as illustrated in Figure 2 Figure 2 Three 10V Units Output Short Plates Assembly Connection Plate 3U Plain Washer No...

Page 5: ...connector to bottom unit S connector as illustrated in Figure 3 Figure 3 Three 10V Units Paralleling Cable Connection 4 Insert output cover through the cables as illustrated in Figure 4 Figure 4 Outp...

Page 6: ...pened in its bottom side Open the insulator and cover the bus bar by sliding it over the bus bar from top to bottom as illustrated in Figure 6 Repeat for the second bus bar Figure 6 Three 10V Units Bu...

Page 7: ...utput cover to the power supplies using six SEMS screws as illustrated in Figure 7 Figure 7 Three 10V Units Output Cover Assembly M3 x 8 SEMS Screw Nickel Plated Tightening torque 4 7 5 7 Lbf inch 0 5...

Page 8: ...omponents List Image Component Quantity 10 32 x 5 16 Pan Head Screw Stainless Steel 12 Helical Spring Lock Washer No 10 Stainless Steel 12 Plain Washer No 10 Stainless Steel 12 Connection Plate 3U 2 O...

Page 9: ...9 Image Component Quantity Bus Bar Insulator 2 Protection Insulator 1 M3 x 8 SEMS Screw Nickel Plated 8...

Page 10: ...ach output short plates one on each triple of terminals using eight flat head screws as illustrated in Figure 9 Figure 9 Three 20V 40V Units Output Short Plates Assembly Connection Plate 3U Plain Wash...

Page 11: ...nnector to bottom unit S connector as illustrated in Figure 10 Figure 10 Three 20V 40V Units Paralleling Cable Connection 4 Insert output cover through the cables as illustrated in Figure 11 Figure 11...

Page 12: ...its bottom side Open the insulator and cover the bus bar by sliding it over the bus bar from top to bottom as illustrated in Figure 13 Repeat for the second bus bar Figure 13 Three 20V 40V Units Bus B...

Page 13: ...embly 8 Fix protection insulator to the output cover using two SEMS screw as illustrated in Figure 15 Figure 15 Three 20V 40V Units Protection Insulator Assembly M3 x 8 SEMS Screw Nickel Plated Tighte...

Page 14: ...Components List Image Component Quantity 10 32 x 5 16 Pan Head Screw Stainless Steel 12 Helical Spring Lock Washer No 10 Stainless Steel 12 Plain Washer No 10 Stainless Steel 12 Connection Plate 3U 2...

Page 15: ...15 Image Component Quantity Bus Bar Protection Bracket 1 Bus Bar Cover Plug 6 M3 x 8 SEMS Screw Nickel Plated 8...

Page 16: ...ttach output short plates one on each pair of terminals using six flat head screws as illustrated in Figure 17 Figure 17 Three 60V 100V Units Output Short Plates Assembly Connection Plate 3U Plain Was...

Page 17: ...r insert six bus bar cover plugs into the bus bar protection bracket and fix it to the output cover using two SEMS screw Insert output cover assembly through the cables as illustrated in Figure 19 Fig...

Page 18: ...Assembly 6 Assemble one lug on each bus bar using one hexagon bolt two plain washers one helical spring lock washer and one hexagon nut as illustrated in Figure 21 Figure 21 Three 60V 100V Units Lugs...

Page 19: ...U 150 600V Assembly Instructions for three 150V 600V units in Parallel 1 4 4 1 Components List Image Component Quantity 10 32 x 5 16 Pan Head Screw Stainless Steel 12 Helical Spring Lock Washer No 10...

Page 20: ...nent Quantity Paralleling Cable 2 Fixing Bracket 1 M3 x 8 SEMS Screw Nickel Plated 6 Output Bracket G 15KW 1 M3 x 10 SEMS Screw Nickel Plated 4 Output Bracket 1 M3 x 6G Flat Head Screw Nickel Plated 2...

Page 21: ...e 150V 600V Units Connection Plates 2U Assembly 2 Loose and remove six flat head screws from power supply s back side as illustrated in Figure 24 Figure 24 Power supply s back side screws removal Conn...

Page 22: ...ing bracket installation 4 Insert three plugs into their compatible output receptacle and fasten them using their six built in screws and a slotted screwdriver as illustrated in Figure 26 Figure 26 Fi...

Page 23: ...KW to fixing bracket using four SEMS screws ten millimeter screw length screws as illustrated in Figure 27 Figure 27 Output bracket G 15KW installation M3 x 10 SEMS Screw Nickel Plated Tightening torq...

Page 24: ...e 28 Output bracket installation 7 Connect two paralleling cables from top unit M connector to bottom unit S connector as illustrated in Figure 29 Figure 29 Three 150V 600V Units Paralleling Cables Co...

Page 25: ...o operate the power supply use the output plug and fasten it using its two built in screws as illustrated in Figure 30 Figure 30 Output plug Output plug Built in screws Tightening torque 3 8 Lbf inch...

Page 26: ...26 This page intentionally left blank...

Page 27: ...__ _________________________________________________ _________________________________________________ _________________________________________________ _______________________________________________...

Page 28: ...__ _________________________________________________ _________________________________________________ _________________________________________________ _______________________________________________...

Reviews: