TDK-Lambda FPS1000-12 Instructions Manual Download Page 3

FPS

A-49

・All specifications are subject to change without notice.

FPS1000/P

REAR VIEW

FRONT VIEW

AIR FLOW 

DIRECTION

SEE NOTE 2

OUTPUT CONNECTOR SEE NOTE 1

AC CABLE 

LOCK OPTION

IEC320 

AC INLET

1

2

3

4

5

6

7
8
9

19
20
21 22

23

24

SEE NOTE 4

3 MOUNTING HOLES M3 MARKED "A" SEE NOTE 3

FUNCTION

FUNCTION

DC̲OK
SIGNAL̲RTN
AC̲FAIL
TEMP̲ALARM
-S
V̲TRIM
CS
+12V̲AUX

PIN

NUMBER.

PIN

NUMBER.

+v
+v
-v
+v
-v
-v
ON/OFF
+S

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

  10
  11
  12
  13
  14
  15
  16

FUNCTION

SDA (I

2

C)

SCL (I

2

C)

A0 (I

2

C)

A1 (I

2

C)

A2 (I

2

C)

NC
NC
NC

PIN

NUMBER.

  17
  18
  19
  20
  21
  22
  23
  24

NOTES

1. CONNECTOR TYPE: PCIB24W9M400A1, PO-

SITRONIC.  FEMALE  CONNECTOR  TYPE: 

PCIB24W9F400A1,-S1031(not  attached  with 

unit)

2. LED INDICATORS. REFER TO INSTRUCTION 

MANUAL.

3.  MOUNTING  SCREWS  MUST  NOT  PENETR-

ATE MORE THAN 3mm INTO THE UNIT.

4. MODEL NAME, INPUT AND OUTPUT RATING 

AND  SAFETY  APPROVALS  SYMBOLS  ARE 

DESCRIBED ON TOP SURFACE LABEL.

5. ALLOW MINIMUM 50mm OF UNRESTRICTED 

AIR SPACE AT THE REAR OF UNIT. DO NOT 

OBSTRUCT AIR FLOW TO THE UNIT FRONT 

PANEL.

6. IN OUT CONNECTOR BACK VIEW AND PINS 

ASSIGNMENT:

AIR FLOW

DIRECTION

IN/OUT CONNECTOR

SEE NOTE 1

3 MOUNTING HOLES M3 MARKED "A" SEE NOTE 3

SEE NOTE 2

1

2

3

4

5

6

7
8
9

19
20
21 22

23

24

FUNCTION

FUNCTION

DC̲OK
SIGNAL̲RTN
AC̲FAIL
TEMP̲ALARM
-S
V̲TRIM
CS
+12V̲AUX

PIN

NUMBER.

PIN

NUMBER.

+v
+v
-v
+v
-v
-v
ON/OFF
+S

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

  10
  11
  12
  13
  14
  15
  16

FUNCTION

SDA (I

2

C)

SCL (I

2

C)

A0 (I

2

C)

A1 (I

2

C)

A2 (I

2

C)

ACG
ACL
ACN

PIN

NUMBER.

  17
  18
  19
  20
  21
  22
  23
  24

NOTES
1. CONNECTOR TYPE: PCIB24W9M400A1, POS-

ITRONIC. FEMALE CONNECTOR TYPE: PCIB-
24W9F400A1,-S1031(not attached with unit)

2.  LED  INDICATORS.  REFER  TO  INSTRUCTION 

MANUAL.

3. MOUNTING SCREWS MUST NOT PENETRATE 

MORE THAN 3mm INTO THE UNIT.

4.  MODEL  NAME,  INPUT AND  OUTPUT  RATING 

AND  SAFETY  APPROVALS  SYMBOLS  ARE

 

DESCRIBED ON TOP SURFACE LABEL.

5. ALLOW  MINIMUM  50mm  OF  UNRESTRICTED 

AIR  SPACE AT  THE  REAR  OF  UNIT.  DO  NOT 
OBSTRUCT AIR  FLOW  TO  THE  UNIT  FRONT 
PANEL.

6.  IN  OUT  CONNECTOR  BACK  VIEW AND  PINS 

ASSIGNMENT:

REAR VIEW

FRONT VIEW

SEE NOTE 4

(unit: mm)

(unit: mm)

FPS1000

Outline Drawing

FPS

 1000