background image

DTM70, DTM70-C8 Manual

 

External AC-DC Power Adapters, 70W 

 

Hold-up time 

Min. 
Typ. 

8ms 
10ms 

For all models at 115Vac input voltage 

Operational temperature range 

 

-30°C to +60°C 

For derating see chapter “Environment” 

Storage temperature rang 

 

-40°C to +85°C 

 

Size 

 

120 x 52 x 31mm 
(4.72 x 2.05 x 1.22”) 

Length x Width x Height 

Weight 

 

300g (0.66lb) 

Without input cable 

MTBF 

Min. 

500 000h 

Acc. to MIL HDBK 217F at full load, GB25°C 

Warranty  

years 

 

10. E

FFICIENCY 

C

URVES

 

DTM70CN120, DTM70CN120C8: 
Efficiency vs. output load

 

DTM70CN150, DTM70CN150C8: 
Efficiency vs. output load

 

 

 

DTM70CN180, DTM70CN180C8: 
Efficiency vs. output load

 

DTM70CN240, DTM70CN240C8: 
Efficiency vs. output load

 

 

 

DTM70CN360, DTM70CN360C8: 
Efficiency vs. output load

 

DTM70CN480, DTM70CN480C8: 
Efficiency vs. output load

 

 

 

All parameters are typical values specified at nominal input voltage, nominal output load, 25°C ambient and after a 5 minutes run-in time unless  
otherwise noted. The information presented in this document is believed to be accurate and reliable and may change without notice. 

For additional information, please visit 

https://product.tdk.com/en/power/dtm

 

7/13

DOC-ID: 260932 – Issue 1

Summary of Contents for DTM70 Series

Page 1: ...Curves 7 11 EMC 8 12 Physical Dimensions Weight and Connectors 9 13 Environment 10 14 Isolation and Dielectric Strength 11 15 Safety and Protection Features 11 16 Approvals and Regulatory Compliances...

Page 2: ...compact design achieved by the high efficiency and the standard locking DIN output connector which prevents unintentional output voltage disconnection Other connector versions and cable assemblies are...

Page 3: ...he device is designed to operate in areas with a maximum relative humidity of 93 4 INSTALLATION INSTRUCTIONS Before operating this device please read this manual thoroughly and retain this manual for...

Page 4: ...If the capacitive load is higher than the values specified the device operates in an intermittent mode hiccup mode See short form data table for maximum values The output voltage is fixed and can not...

Page 5: ...70CN480 External Adapter Power Supply Class I 70W 48V 1 5A DTM70CN120C8 External Adapter Power Supply Class II 70W 12V 5 8A DTM70CN150C8 External Adapter Power Supply Class II 70W 15V 4 65A DTM70CN180...

Page 6: ...90 and 264Vac Load regulation Max Max Max 5 3 2 For DTM70CN120 DTM70CN120C8 For DTM70CN150 DTM70CN150C8 For all remaining models For 60 40 load steps Ripple and noise voltage Max Max Max Max Max Max...

Page 7: ...0CN120C8 Efficiency vs output load DTM70CN150 DTM70CN150C8 Efficiency vs output load DTM70CN180 DTM70CN180C8 Efficiency vs output load DTM70CN240 DTM70CN240C8 Efficiency vs output load DTM70CN360 DTM7...

Page 8: ...les class 3 80Vac 250 300 cycles class 3 Criterion A Criterion A Criterion B Criterion A Criterion A Voltage interruptions EN 61000 4 11 EN 60601 1 2 AC 100 120 230Vac 0Vac 250 300 cycles class 3 Crit...

Page 9: ...tor Kycon KPPx 4P or equivalent P1 P2 Vout P3 P4 Vout Alternative output connectors are available Please contact sales for further information minimum quantities apply All parameters are typical value...

Page 10: ...rding to IEC 60664 1 Degree of pollution 2 According to IEC 62477 1 not conductive Vibration sinusoidal 4g 15 2000Hz 60 minutes per axis According MIL STD 810F Table 514 5C VIII sinusoidal vibration u...

Page 11: ...70CN180 DTM70CN180C8 For DTM70CN240 DTM70CN240C8 For DTM70CN360 DTM70CN360C8 For DTM70CN480 DTM70CN480C8 In case of an internal defect a redundant circuit limits the maximum output voltage The output...

Page 12: ...ical equipment Part 1 General requirements for basic safety and essential performance Part 1 6 Collateral standard Usability Part 1 11 Collateral Standard Requirements for medical electrical equipment...

Page 13: ...ted The information presented in this document is believed to be accurate and reliable and may change without notice For additional information please visit https product tdk com en power dtm 17 PACKA...