6. Wiring Method

(1) The output load line and input line shall be separated, and use all lines as thick and short as possible to make

lower impedance. The output load line and input line shall be twisted or use shielded wire to improve noise 
sensitivity.

(2) Noise can be eliminated by attaching a capacitor to the load terminals.
(3) EMI reduction performance by winding the cable around the appropriate ferrite core or clamp core.
(4) For safety and elimination of noise considerations, connect       terminal to ground terminal of the equipment.
(5) The recommended wire type, torque and crimp­type terminal :

Block terminal type

Note 1 : When using separate loads, use of two pcs. of 0.8mm thick crimp­type terminal is recommended.
Note 2 : For recommended diameter, refer to wire maker recommended allowable current and voltage drop.
Note 3 : Use wires rating at least 75

and copper conductor only.

Note 4 : Use crimp­type terminal for connection to terminal.

European terminal type

Note 5 : Use wires rating at least 75

and copper conductor only.

Solid wire is possible to push­in. In case of using stranded wire, connect by the following method.
Pushing the lever by using tool, such as a flat scewdriver, insert wire until stripped part isn

t seen any more,  

and then remove tool. After wiring, confirm that wire is connected to terminal certainly.
Lack insertion of wiring or slack of wiring might cause electric shock, fire or damage of equipment.
Strip the wire by recommended stripping length.

When remove solid wire and stranded wire, remove them while pushing the lever by using tool, such as a flat 
scewdriver.

MODEL

DRJ15/E
DRJ30/E
DRJ50/E
DRJ100/E

Recommended

Wire

Recommended Wire to be stripped

8 ~ 10mm

AWG14­20

wire entry holes

lever

Recommended torque

Recommended crimp­type terminal

D

MAX

Mounting 

piece

MAX

t

MAX

6.8mm

1piece

1.0mm

Input, Output terminal M3.5 Screws
1.0­1.4N

(10.2­14.2kgf

cm) (8.85­12.39lb

in)

Recommended  

Wire 

AWG16­20

Model

DRJ15
DRJ30

2pieces

0.8mm

terminal M3.5 Screw

1.0N

m

(10.2kgf

cm, 8.85lb

in)

1piece

1.0mm

2pieces

0.8mm

All terminal M3.5 Screws
1.0­1.4N

(10.2­14.2kgf

cm) (8.85­12.39lb

in)

DRJ50

DRJ100

1piece

1.0mm

2pieces

0.8mm

6.8mm

8.0mm

Summary of Contents for DRJ15

Page 1: ...t drop or apply shock to this product It might cause failure Do not operate these products mechanical stress is applied CAUTION Do not use this product in special environment with strong electromagnet...

Page 2: ...rminal Output voltage adjustment trimmer DRJ100 C2 and C2E do not have L Input terminal Live line Fuse in line N Input terminal Neutral line PE Protective earthing terminal Output monitoring indicator...

Page 3: ...15 DRJ30 Input Output terminal 1 0N m 10 2kgf cm 1 4N m 14 2kgf cm DRJ15 DRJ30 terminal 1 0N m 10 2kgf cm DRJ50 DRJ100 Input Output terminal terminal 1 0N m 10 2kgf cm 1 4N m 14 2kgf cm DRJ15 E DRJ30...

Page 4: ...select input switch and fuse carefully with the high temperature and re input the power condition The inrush current value is under cold start at 25 in the specification Regarding the external fuse p...

Page 5: ...e diode 2 Please adjust the output voltage of each power supply to be the same 3 Please use within the specifications for output voltage and output power 4 Please select a reverse current prevention d...

Page 6: ...tester may generate high voltage at the matching with monolithic ceramic capacitor and may cause the unit damage So please check the waveform of applied voltage Note 2 In case of using external noise...

Page 7: ...load DRJ15 DRJ30 DRJ50 Include option model E DRJ100 Include option model E C2 C2E 7 14 L N DRJ100 24 1 24VDC 4 2A V V V V ADJ DC OK 100 240VAC 24VDC 1 25A V ADJ 100 240VAC V N V L DRJ30 24 1 DC OK L...

Page 8: ...d safety 85 90 264 80 100 Mounting A B Input Voltage VAC Load 85 100 264 80 100 Mounting A B Input Voltage VAC Load DRJ15 DRJ30 DRJ50 DRJ100 15mm 15mm 15mm 25mm X Surrounding space definition Mounting...

Page 9: ...70 50 Load 20 10 35 40 55 Mounting A 50 100 100 80 Ta o C Mounting B 50 100 90 60 70 40 30 Mounting B Mounting A Mounting B Mounting A Mounting B Mounting A Mounting B Mounting A 0 20 40 60 80 100 120...

Page 10: ...terminal type Note 5 Use wires rating at least 75 and copper conductor only Solid wire is possible to push in In case of using stranded wire connect by the following method Pushing the lever by using...

Page 11: ...dition of rated input voltage and 24 hour continuous operation Load is percent of maximum output power or maximum output current do not exceed its derating of maximum load DRJ15 Mounting A Mounting B...

Page 12: ...rrent value at input turn on Do not select the fuse according to actual input current rms values DRJ15 DRJ30 2 5A DRJ50 DRJ100 3 15A 10 Power supply mounting on DIN RAIL DRJ series conforms to TS35 si...

Page 13: ...ut is correct 3 Check if the wire size is not too thin 4 Check if the output voltage control V ADJ is properly adjusted 5 Check if the output current and output power does not over specifications 6 Au...

Page 14: ...within this warranty period repair is free of charge Please contact our sales office for warranty in other mounting directions if required DRJ15 DRJ30 DRJ50 DRJ100 Following cases are not covered by w...

Reviews: