background image

 

Page 

1

 of 

11

 

 

TDK-Lambda 

DBM20 

 

INSTRUCTION MANUAL

 

PA640-04-01B 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

   

 

 

 

DBM20 Instruction Manual 

  

BEFORE USING THE PRODUCT 

 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage 
may lead to an electrical shock, damage to the unit or a fire hazard. 

 

  DANGER

 

 

  Never use this product in locations where flammable gas or ignitable substances are present. 

        

  DANGER

 

          Ne jamais utiliser ce produit en présence de substances inflammables ou explosives. 

 

  INSTALLATION WARNING

 

 

When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, there is risk of electric shock and fire. 

 

Installation shall be done by service personnel with necessary and appropriate technical training and experience. There is a risk of electric shock and fire. 

 

Do not cover the product with cloth paper or etc. Do not place anything flammable around. This might cause damage, electric shock or fire. 

  WARNING ON USE

 

 

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a burn. 

 

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. 

 

There are cases where high residual voltage remains inside the product. Therefore, do not touch even if they are not in operation as you may get injured due to 
high voltage and high temperature. You may also get electric shock or burn. 

 

Do not make unauthorized changes to this product nor remove the cover as you may get an electric shock or may damage the product. We will not be held 
responsible after the product has been modified, changed or disassembled. 

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop using it immediately and turn off the 
product. It may lead to fire and electric shock. In such cases, please contact us. Do not attempt to repair, as it is dangerous for the user. 

 

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It may lead to fire or electric shock. 

 

Do not drop or apply shock to this product. It may cause failure. Do not operate these products when mechanical stress is applied. 

          PRECAUTIONS D’USAGE

 

 

Ne pas toucher ce produit ou l’un de ses composants internes pendant qu’il est sous tension, ou peu après la mise hors tension.  Vous pourriez vous brûler. 

 

Ne pas modifier ce produit sans autorisation ni retirer son capot, vous pourriez recevoir une décharge électrique  
ou endommager le produit. Nous ne saurions être tenus responsables après que le produit ait été modifié, changé  
ou démonté. 

 

Ne pas utiliser ce produit dans des conditions anormales comme la présence de fumées ou d’odeurs inhabituelles ou de bruits suspects etc. Merci d’arrêter 
l’utilisation immédiatement et d’éteindre le produit. Il pourrait se produire un feu ou un choc électrique. Dans de tels cas, merci de nous contacter. Ne pas 
essayer de réparer le produit, c’est dangereux pour l’utilisateur. 

 

Ne pas utilizer oustocker le produit dans un environnement exposé à la condensation ou à l’humidité Cela peut provoquer un feu ou un choc électrique. 

 

  

CAUTION ON MOUNTING 

 

Follow connections to input/output terminals indicated in the instruction manual before switching on. 

 

Input/output wires are to be short and thick as possible. 

 

Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and direct sunlight, or places where 
product is exposed to water or rain. 

 

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly ventilated. 

 

Please turn off  the input power when doing wiring to connect to the input/output of the product. 

 

When installing in environment where conductive foreign, dust and liquid may be present, please consider penetration and take actions to prevent the above 
foreign material from entering the buffer module by installing filter. In order to prevent trouble or malfunction. 

 CAUTION ON USE

 

 

Product individual notes are shown in the instruction manual. If there is any difference with common notes, individual notes shall have priority. 

 

Before using this product, be sure to  read the catalog and instruction manual. There is risk of electric shock or damage to the product or fire due to improper 

use. 

 

Input voltage, Buffer current, Buffer power, ambient temperature and ambient humidity should be kept within specifications, otherwise the product will be 
damaged, or cause electric shock or fire. 

 

If the built-in fuse is blown, do not use the product even after replacing the fuse, as there is risk of abnormality inside. Kindly request repair to our company. 

 

This  product with built-in protection circuit, depending on usage conditions, built-in protection circuit may not work. It is recommended to provide a separate 
protection circuit (element, fuse, etc.), insert fuse at the input to prevent smoke, fire during  abnormal operation. 

 

This product is made for general purpose electronic equipment use and is not designed for applications requiring high safety (such as extremely high reliability 
and safety requirements. Even though high reliability and safety are not required, this product should not be used directly for applications that have serious risk 
for life and physical safety). Take sufficient consideration in fail-safe design (such as providing protective circuit or protective device inside the system).  

 

When used in environments with strong electromagnetic field, there is possibility of product malfunction.

 

 

Summary of Contents for DBM20

Page 1: ...Ne pas utiliser ce produit dans des conditions anormales comme la pr sence de fum es ou d odeurs inhabituelles ou de bruits suspects etc Merci d arr ter l utilisation imm diatement et d teindre le pro...

Page 2: ...environnement o des particules conductrices de la poussi re ou des liquides peuvent tre pr sents merci d installer des filtres afin de pr venir toute intrusion de corps trangers l int rieur du produi...

Page 3: ...Earth Terminal RED LED Discharging Indicator LED will be ON during Buffering mode GREEN LED Charged Indicator LED will be ON during Ready mode DC OK Relay Photo Mosfet Logic low when input voltage is...

Page 4: ...which is out of specification or reversed may damage the unit 4 2 Nominal Buffer Voltage Range 4 2 1 Fixed mode during buffering mode the nominal buffer voltage level 22 4VDC 4 2 2 VIN 1 mode during b...

Page 5: ...uffer module provides two option for buffer voltage that is fixed mode and Vin 1 mode Executed using toggle switch to choose between the two options refer to Figure 1 At fixed mode the buffer voltage...

Page 6: ...C input to the power supply the output from the power supply which is connected to the input output of the buffer module will charge up the internal circuit of the buffer module 2 Once the input outpu...

Page 7: ...ffering take place buffer signal will change from logic low to high And Ready signal will change from logic high to low 6 During the upstream power supply is still turn ON case and customer system wil...

Page 8: ...limit of withstand voltage test equipment at 100mA The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down When timer is used the buffer m...

Page 9: ...ng Please refer to section 6 Leave enough space surround the units to ventilate heat efficiently Minimum Installation clearances 40mm on top 20mm at the bottom A 5mm which is recommended on the left a...

Page 10: ...citor varies depending on the method of mounting the buffer module the load current and the ambient temperature Please refer to the Electronic Capacitor Lifetime Please do not use the product which pa...

Page 11: ...Ltd Sales Services and R D 1008 Toa Payoh North 06 01 08 07 01 03 Singapore 318996 Telephone 65 62517211 Facsimile 65 62509171 WEBSITE www tdk lambda com sg Note Name plate s contents shown in this in...

Reviews: