TDK-Lambda CUS100MB Series Instruction Manual Download Page 11

INSTRUCTION MANUAL

CUS100MB

TDK-Lambda

<Page>

5-3. Mounting Method
5-3-1. Mounting method for standard model

Note: Except /A, /B and /G2 model.
All four mounting holes on this model should be utilized for best electrical and mechanical performance, with 8mm 
(minimum height) metal standoffs.

Mounting Holes size

4 holes

φ

3.5mm. 

Refer to the shadow in the figure below for allowable area touched by conductive material on top and bottom side of the PCB.

Condition to meet EMI, EMC, Isolation, Withstand Voltage and Cooling requirement.

Keep 4mm space minimum from the surface and sides of power supply, 8mm space minimum from the bottom side of PCB to meet safety 
requirement, or more space depend on safety requirement. If the space is not enough, the specification of isolation and withstand voltage will 
not be satisfied. 
More space may be required in the surrounding of power supply and the upper area of components for effective cooling 
depends on the application conditions.

terminal (Protective Earth) must be connected to the earth terminal of the equipment, also the two mounting holes (as 

shown below) needed to be connected to earthed metal plane or metal chassis of end product by metal spacer to ensure EMC 
and EMI performance.
All equipment ideally should be mounted inside an earthed shielded metal box. Alternatively an earthed metal plate can be 
used to mount the power supply and load. 

Height more than 8mm spacer

11/14

6

6

R3

6

6

R3

6

6

6

6

R3

R3

Earth Terminal

Wire

Terminal

Metal spacers

Summary of Contents for CUS100MB Series

Page 1: ...ould be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensation might occur In such case waterproof treatment is nec...

Page 2: ...eeClause16 IEC UL60601 1 2 TheseproductsareNOTsuitableforuseinthepresenceofflammableanaestheticmixtures with air or with oxygen or withnitrous oxide 3 Theseproductsareclassedasordinary equipment accor...

Page 3: ...tion Output Terminal OutputTerminal V ADJ Output voltage adjusttrimmer Theoutput voltageriseswhenthetrimmeristurnedclockwise Mountinghole holediameter 3 5mm Thishole isusedforsupporttheunit 3 Terminal...

Page 4: ...creased Take note when the output voltage is increased excessively over voltage protection OVP function may be triggered and voltage will be shut down Furthermore when increasing the output voltage re...

Page 5: ...rding to measurement circuit specified as below When load lines are longer ripple will becomes larger In this case electrolytic capacitor film capacitor etc might be necessary to use across the load t...

Page 6: ...ed voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by high impulse voltage at timer swi...

Page 7: ...for models except CUS100MB A Recommended standard mounting direction is A Mounting direction B E are also possible A Standard mounting B C D E 5 1 2 Mounting directions for CUS100MB A Recommended stan...

Page 8: ...2 12V 15V 18V model 3 24V Model 8 14 Convection and Force Air Cooling Mounting A B C D E Ta C Load 20 50 100 70 50 Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load...

Page 9: ...C D E Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load Load 100 50 70 40 Ta C 20 30 100 20 50 50 80 70 Convection Cooling Force Air Cooling Mounting A B C D E Mount...

Page 10: ...ing components will not exceed max temperature in the table Absolutetemperature Temperaturerise Ambient temperature 5 2 2 Output derating for CUS100MB A CUS100MB A is convection cooling type Makesuret...

Page 11: ...uirement or more space depend on safety requirement If the space is not enough the specification of isolation and withstand voltage will notbesatisfied More space may be required in the surrounding of...

Page 12: ...ied More space may be required in the surrounding of power supply and the upper area of components for effective cooling depends on the application conditions All equipment ideally should be mounted i...

Page 13: ...nal filtering may be required depends on application and installation methods Pleaserefertofollowingapplicationnotes whichmayhelptoimproveEMCperformance 1 The output load line and input line shall be...

Page 14: ...ies but not limited to the following 1 Average operating temperature ambient temperature of the power supply unit is under 40 2 3 years warranty base on 24 hours day operation at 100 load Please refer...

Reviews: