background image

Digalox

®

 DPM72-AV Instruction manual 

(Rev-2022-07)

Package contents: 

Panel meter Digalox

®

 DPM72-AV, mounting bracket, 5 jumpers,

2 instruction manuals (EN + DE)

1. Intended use

Measurement   of   current,   voltage   and   frequency   in   the   specified   measuring 
ranges.

Indoor use non condensing, non corrosive.

Panel mounting.

Failure to comply with these instructions will void all guarantee and warranty.

2. Safety instructions

Read instruction manual carefully before operating the device! Keep for later ref-
erence.

Mounting and installation must be carried out by suitably qualified and competent 
persons only.

WARNING: The measurement inputs of the device can carry life-threaten-
ing voltages!

WARNING: When working on the device hazardous voltages must not be 
connected   to   the   device!   The   terminals   J1-J6   are   not   isolated   from   the 
measuring circuit.

The device is not intended to protect persons or facilities against harm. Specific 
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).

When connecting switches to the terminals J1-J6, only switches must be used 
whose isolation voltage is at least twice the maximum occurring measurement 
voltage. For example, when measuring 250 V AC switches must be isolated for 
at least 500 V.

Do not open the housing!

Do not use the device in the presence of explosive or flammable substances!

All cables carrying hazardous voltages must be secured with external separators.

----- 

1

 -----

Summary of Contents for Digalox DPM72-AV

Page 1: ...ement inputs of the device can carry life threaten ing voltages WARNING When working on the device hazardous voltages must not be connected to the device The terminals J1 J6 are not isolated from the...

Page 2: ...ernal switch The measured values remain stored as long as the device is supplied with voltage 2 4 3 1 Front 1 Measurement unit 2 Upper scale caption 3 Graphical measurement display 4 Digital measureme...

Page 3: ...rrent via current transformer and voltage direct Digalox Load Current transformer Ilow Ihigh Uhigh Ulow max 10 A FF L N max 500 V Current via current transformer on high side and voltage direct Digalo...

Page 4: ...easurement modes via an external switch Save mode The required measurement modes are configured and saved sequentially 1 Set DIP switch 10 11 and 12 to OFF position 2 Connect supply voltage 3 Set the...

Page 5: ...iguration proceed as follows 1 Connect supply voltage 2 Set DIP switches 1 9 to OFF position 3 Set DIP switch 10 to ON position 4 Start with 1st switch 5 Set switch to ON position 6 If the displayed v...

Page 6: ...4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 A AC direct Ampere AC ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 V DC direct Volt DC ON 1 2 3 4...

Page 7: ...e setting permanently DIP switch 10 must be switched from ON to OFF position J2 Min Max display The display shows the maximum and min imum values recorded since the last reset The values can be reset...

Page 8: ...requency 10 1000 Hz Accuracy frequency 0 1 Hz Measuring value update 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 internal memory locations Operating temperature 0 C to...