FSEC APPROVED 2-WAY SYSTEMS
FSEC SECTION
:
The following procedures are required for FSEC approved systems:
1. The FSEC Approved Solar Energy System plumbing schematic must be followed when
installing the system.
2. All standards in the FSEC-GP-7-80 must be met.
3. Place the Freeze Protection sticker provided on the conventional water heater in a place
that is noticeable and easy for the homeowner to read. If the sticker is lost or damaged,
type a new one and tape it with clear tape on the tank (completely cover the label with
clear tape to protect it). Label must read as follows: (
SEE LABEL A
)
4. Place the “Refilling Your Collector” label on the return line boiler drain. If label is
damaged or missing, type a new one on heavy paper stock and seal in clear plastic to
make it waterproof. Attached the label with wire or plastic tie. Label must read as
follows: (
SEE LABEL B)
5. Give homeowner a copy of the Owner’s Manual, FSEC Certifications Warranty and local
phone number of the installing contractor. Go over all operations of the system and how
to obtain warranty service if needed.
LABEL A:
Freeze Protection Information
The freeze protection method of this system is thermal mass and manual draining. In some areas an
automatic freeze prevention valve may have been installed. This valve will open during freezing
weather and allow a small flow of water. Drain the system as instructed in the Owner’s Manual when
air temperatures of 10°F or below are expected.
LABEL B:
IMPORTANT READ BEFORE REFILLING YOUR COLLECTOR
If you have drained your collector for any reason, it is most important that the collector be vented to
the atmosphere during refilling. Refer to the Owner’s Manual or the directions on the other side of
this tag. Only potable water is to be used in this system
.
WARNING: WATER COULD BE DISCHARGED AT HIGH TEMPERATURE
AND/OR PRESSURE