Function description 

To listen-in into rooms  

It must be guaranteed that there is no way to listen-in into the room, in which the ISW3330 
is installed, without the permission from the resident via keystroke at the call button. Lis-
ten-in into the room is only possible, if the resident has called the central (by pressing the 
call button, the floor push button or the radio sensor button) or if he presses the call button 
or the radio sensor once when the connection is being established (accept voice connec-
tion  or in case of a single announcement from the central). 
 

To speak into rooms  

After a call from the indoor station, a person at the central can speak-in the room via an 
announcement (single announcement). 
 

Resident calls the central  

  The resident presses the call button at the indoor station, the floor push button, config-

ured with floor call

 

(see

 

Floor

 push button

,

 page 8) or the button of a trained radio send-

er. 

  An acknowledgement tone sounds and the lighting bar lights red.  

  The person in the central calls the resident. A ring tone sounds at the indoor station, the 

lighting bar lights green. To communicate with the central, no further action by the resi-
dent is required. 

  The person at the central can speak into and listen-in into the room. (The central can 

change the speech direction. Thus, the resident could talk to the central, if he is within 
earshot of the indoor station.) 
 

Floor push button 

  Pressing the floor push button creates a floor call (= factory setting), which is recog-

nized by the central.  
At the ISW3330 sounds the configured floor ring tone as confirmation for the resident. 
The central can analyse these signals: and allows these signals and can return the call 
and allow to listen-in into rooms. 

  The floor push button can be used as opening or closing contact. The indoor station can 

be configured accordingly with the configuration 

software configo™. 

 

!

 

The floor push button cannot be used to accept calls! 

 
 

Radio module 

  A radio receiver board (article no. 0022930) can be built-in. Thus, it is possible to trigger 

the call also via radio push button, which are available as necklace and bracelet (article 
no. 0022931, article no. 00229310022932)  

 

!

 

When planning the system, please observe that a radio transmission can be limited 
geographically or can be disturbed.  

 

Summary of Contents for ISW3330

Page 1: ...rolSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISW3330 uk 2 A Product information Indoor station for hands free talking with special functio...

Page 2: ...ion 9 Installation site 9 Install the lower cover 9 Connect the lines 10 Snap on the upper cover 10 Open the device 10 Installation of extended functions 11 Built in call relay TRE1 EB 1 11 Radio rece...

Page 3: ...07 2015 3 TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISW3330 uk 2 A Spare parts accessory 18 Information 19 Service 20...

Page 4: ...eter existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance Installation protective measures With suitable measures to protect against lightning...

Page 5: ...10 AS front door station VS power supply and control unit IS indoor station Note The max number of AS which can be connected is limited and is descriped in their respective product infor mation Techn...

Page 6: ...led duplex communi cation after an incoming door call or internal call calling the central allow to listen in into rooms end the communication Lighting bar Is ON red indication of a sent call to the c...

Page 7: ...o allow listen in into rooms Short description manually controlled duplex communication speech direction is determined by central large call button no door release button and no call OFF button optica...

Page 8: ...ng bar lights red The person in the central calls the resident A ring tone sounds at the indoor station the lighting bar lights green To communicate with the central no further action by the resi dent...

Page 9: ...ed living The device supports the protocols for assisted living AL During the AL phase manually controlled duplex communication cannot be implemented An established voice connection is ended by the AL...

Page 10: ...to the labelling a b E P from the buttom to the top floor push button at a E Wiring example see page 12 Snap on the upper cover Place the upper cover at both adjustment increments of the lower cover...

Page 11: ...dule Push the contact pins of the radio receiver board into the designated socket position see adjoining illustration Ensure that all six pins of the plug of the small PCB are plugged into the socket...

Page 12: ...2 A Connect the lines Connection lines acceptable cross section diameter 0 08 0 82 mm2 0 32 1 0 mm max number of wires per terminal contact each 2 x 0 8 mm 3 x 0 6 mm Connect further wires with auxil...

Page 13: ...ompletely Check the a b and P wire against each other for short circuits Switch ON the mains voltage Note floor push button If the floor push button does not work check if it is connected to the a wir...

Page 14: ...ol OFF always max volume floor push button as opener closing contact opener optical and acoustic error indication ON OFF OFF Pre set times communication time max 2 min call standby time 2 min if the d...

Page 15: ...to three different groups Thus an announcement can be implemented e g at the floor and alternatively in a staircase Factory setting all three with value 0 can be changed to 1 63 The functions can be c...

Page 16: ...e To keep the max permitted loop resistance the cross section of the wire can be doubled that means for one wire two lines are used illustra tion The lines must be twisted When using shielded lines co...

Page 17: ...urbing the measure ment they can stay connected Measure the resistance at a b at the last IS or AS 8 Ohm max 62 m distance AS IS VS by 0 6 mm diameter max 112 m distance AS IS VS by 0 8 mm diameter AS...

Page 18: ...ection point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electri...

Page 19: ...the radio sensor a manually con trolled duplex communication is established The person at the central can change the speech direction and is able to listen in into the room If the call is not accepted...

Page 20: ...Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISW3330 uk 2 A Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwister Scholl Str...

Reviews: