2 A 

Max. number of ISW3130 in 3-wire operation 

when using power supply 
and control unit 

Max. number 

ISW3130 

 

BVS20 or  
NBV1000, 1 line 

20 

BVS100,  
distributed to 3 lines 

80 

VBVS05, 1 line 

90 

BVS20 + NGV1011,  
1 line 

90 

AS  front-door station 
VS  power supply and control unit 
IS  indoor station 
Note: The number of the front-door stations which can 
be connected is limited. Details are described in their 
product information!

 

NGV1011,  
3 lines 

270 

 
 

Indication and operating elements 

 

 

 

speech button 

  call acceptance, activate speaking,  

manually controlled duplex communication  

  end conversation 

 

 

call OFF button 

 

press short

: ring tone stopper 

 

press for 8 sec

: initiate ring tone selection 

 

 

indicatation call OFF 
(red) 
 
 

 

ON

: call OFF is activated  

 

flashes

: ring tone stopper is deactivated, door release 

automatic or call diversion is activated 

 

flashes OFF

: ring tone stopper is activated, door re-

lease automatic or call diversion is activated 

  fault indication: 

 

both LEDs flashing 

  ring tone selection: both LEDs are ON 

 

function key 

  control function 8,  

alternate allocation can be activated: internal call, door 
release automatic, call diversion  

  ring tone selection internal call 

 

 

call indication 
(green) 

 

ON

: call, speaking activated  

 

blinks

 3 x: voice channel is busy 

  fault indication: 

 

both LEDs flash 

  ring tone selection: both LEDs ON 

 

 

light switch button 

  switching lights 

  ring tone selection floor call (from the flat door) 

 

 

 

door release button 

  open the door 

  to trigger light switch function (if the light switch function 

is activated in the front-door station) 

  ring tone selection door call from front-door station 

 

 

 

volume control for 
voice output and 
ring tone 

adjustable in 8 steps: 

  when voice communication is established 

  when no voice communication is established 

 

Summary of Contents for ISW3130

Page 1: ...TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Product information Comfort indoor station for hands free talking ISW3130...

Page 2: ...the upper cover 7 Open the device 7 Installation of extended functions 8 Connect the lines 8 Connection lines 8 Wiring example 9 Connection diagram 2 wire technique 9 Connection diagram 3 wire techniq...

Page 3: ...separators between heavy and low current lines in shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sectio...

Page 4: ...OFF is activated flashes ring tone stopper is deactivated door release automatic or call diversion is activated flashes OFF ring tone stopper is activated door re lease automatic or call diversion is...

Page 5: ...rs like shown in price list dimensions in mm H 180 x W 100 x D 23 weight 185 g acceptable ambient temperature 5 40 C degree of protection IP30 input current stand by 2 wire operation I a 1 mA 3 wire o...

Page 6: ...oftware configo flat door floor door and internal call a parallel call can be activated with the Service Device TCSK 01 or configo audio privacy function and automatic call cut OFF after 2 min lower c...

Page 7: ...from the button to the top floor push button at a E Wiring example see page 9 Snap on the upper cover Set on the upper cover at both adjustment increments of the lower cover 1 Snap on the upper cover...

Page 8: ...the indoor station with adhesive pads see also product information of each extended function Connecting the lines is implemented in analog to the ISW3030 see product information TRE1 EB 1 Connect the...

Page 9: ...2015 9 TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Wiring example Connection diagram 2 wire technique Connection diagram 3 wire techniq...

Page 10: ...check if it is connected to the a wire of the power supply and control unit Settings Preset times conversation time 2 min flashing period of the green LED if the voice channel is busy after establishi...

Page 11: ...control key until the required ring tone sounds The ring tone selected last is stored 3 Short press the call OFF button Or If no button is pressed for around 8 sec the device end the ring tone select...

Page 12: ...x unlimited communication time x reset to factory settings x If the floor door release function in the EEPROM has been activated and the door release automatic function via function key is switched on...

Page 13: ...other and put it one sided on mass b wire in the power supply optional strand or star formed wiring Table loop resistance cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 7...

Page 14: ...r not supplied connect the a wire or check power supply device is in stand by mode again button stucks press longer than 15 sec remove button at the device or loosen floor push but ton device is in st...

Page 15: ...Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a prog...

Page 16: ...ecting point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electri...

Reviews: