background image

11/2012 

13 

 

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129 

 

PI_ISH3022-uk 

 

 

Initiate 

power supply and control unit 

 

 

 

 
 
 

 

 

  

  shortly press 

LED blinks 

 

 

programming mode of the system is switched on  

 

Delete a button

 a)

 

 

 

 

 
 
 

   

 

 
 

 
 
 

 

 

 

press until the deletion melody sounds 

1)

 

 

release 

 

Programming via voice connection  

 

 

 
 
 

 

 
 

 

 
 
 

 

 

 

 
 
 

 

 

 

 

 

establish voice connection 
to the front-door station  

2)

 

 

shortly press 
the button 

… 

 

... a ring tone sounds at the front-
door and indoor station

1)

 

 

put down 
the handset 

 

End 

 

 

 

 

 
 
 

 

 

 

  shortly press            LED is on 

 

programming mode of the system is switched off *

)

 

 
a) Not necessary, if the bell buttons have not been programmed, comp. product information of the front-door station. 
1) If there sounds a Progsperr tone instead, the front-door station is equipped with a programming lock.  

The programming lock can be deactivated only with the Service Device TCSK-01 or the configuration software 
config

o™. 

2) Newly developed front-door stations (as of 2009) respond to that with a positive acknowledgement, when the serial 

number of the indoor station was received (see product information of the front-door station). 

*)

 

for device specific indication modes of the front-door station see product information of the front-door station 

 
 
 
 
 

Summary of Contents for ISH3022

Page 1: ...TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISH3022 uk Product information Door telephone ISH3022...

Page 2: ...ended functions 7 Connect the lines 8 Connection lines 8 Wiring example 8 Connection diagram 2 wire technique 9 Connection diagram 3 wire technique 9 Note Replace an ISH1030 or TTS1 with an ISH3022 9...

Page 3: ...ding to DIN VDE 0100 must be observed When installing TCS BUS systems the general safety regulations for telecommunication systems according to VDE 0800 must be observed separated conduit of heavy cur...

Page 4: ...s put down if the light switch function is activated in the front door station Intended use The ISH3022 is an indoor station for duplex communication As door telephone it is suitable for the operation...

Page 5: ...product information BVS100 NGV1011 3 strands 270 Short description large blue door release button ring tone volume can be adjusted continuously by a qualified electrician acoustic ring tone distinctio...

Page 6: ...ews to the wall Connect the lines Minimise the length of the lines above the upper cover to place the lines without any problems and do not clamp the lines when snapping on the upper cover Connect the...

Page 7: ...evice Insert a small screwdriver straight and with slight pressure into this opening The upper cover can be removed at the underside 1 Lift the upper cover out of the two upper adjustment increments 2...

Page 8: ...t the lines Connection lines acceptable cross section diameter 0 08 0 82 mm2 0 32 1 0 mm max number of wires per terminal contact each 2 x 0 8 mm 3 x 0 6 mm Further wires have to be connected with aux...

Page 9: ...tion both telephones must be replaced with an ISH3022 Commissioning Install the devices of the system voltage free and completely Check the a b and P wire against each other for short circuits Switch...

Page 10: ...sion 1 3 3 ring tone volume x parallel allocation x x reload to factory setting x Programming with the Service Device TCSK 01 The indoor station is acting as a telephone Use the commands 8 for configu...

Page 11: ...wer supply optional strand or star formed wiring Table loop resistances Line length in m Line diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 50 6 38 3 57...

Page 12: ...0 2 mA I P 0 2 mA max input current I Pmax 60 mA Repair Replace the indoor station program bell buttons Basic principle All devices at the TCS BUS have a unique serial number Programming a bell butto...

Page 13: ...d shortly press LED is on programming mode of the system is switched off a Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there soun...

Page 14: ...mbol shows that the device has to be disposed separately from domestic waste The materials used are recyclable Please do help protecting our environment and dispose the device via a collection point f...

Page 15: ...11 2012 15 TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISH3022 uk...

Page 16: ...de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISH3022 uk Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwister Scholl Str...

Reviews: