background image

HE360A POWERED FLOW-THROUGH HUMIDIFIER

68-0273

4

Fig. 4. Humidifier components.

Fig. 5. Position securing clips.

7.

Position the humidifier housing in the hole (be sure it is 

level), so the locking tabs are in place on the upper and 

lower sheet metal edges of the hole. 

8.

Push in the securing clips until completely seated.

9.

Drill holes and install the three sheet metal screws at 

the top of the humidifier housing. Secure the housing 

with the three remaining screws at the bottom of the 

housing.

10.

Reinstall the humidifier pad assembly in the humidifier 

housing.

IMPORTANT

For proper operation, be sure the mark on the end of 

the humidifier pad is facing up. Check that the water 

feed tube is placed in the guide slots of the humidifier 

housing.

11.

Hook the top of the cover to the housing and secure 

with the thumbscrew located at the bottom of the cover.

WIRING HUMIDIFIER

WARNING

Serious Personal Injury or Equipment Hazard.

Moving parts can cause electrical shock and 

injury.

• Disconnect power supply before installation or 

servicing.

• This device contains a moving fan blade; do not 

operate the humidifier without the cover securely 

attached.

IMPORTANT

All wiring must agree with applicable codes, 

ordinances and regulations.

H8908 Humidistat Wiring Connections

IMPORTANT

• Select models of fan centers include humidifier taps 

so the current sensing relay or sail switch is not 

needed.

• If not using a current sensing relay or sail switch, the 

120V humidifier plug must be energized during 

blower motor cycles for proper operation.

1.

Wire the current sensing relay or sail switch.

2.

Connect only the two yellow wires to the humidity 

control (red wire connections are not used for 

mechanical humidity control).

NOTE: For additional mounting and wiring information, refer 

to the humidity control installation instructions.

Plumbing Saddle Valve

Hot or cold water, either hard or softened, can be used in the 

humidifier.

1.

Use the self-piercing saddle valve included to tap into 

the water supply line at an appropriate location.

CAUTION

Equipment Hazard.

Improper installation can cause equipment 

damage.

Do not use any line connected to an air conditioner.

IMPORTANT

• The saddle valve is not designed to regulate water 

flow; the valve is either open or closed.

• Be sure to install the saddle valve handle pointing 

toward the ceiling to prevent debris from clogging the 

solenoid in-line filter.

NOTE: Lightly clean the copper tubing ends with fine 

sandpaper before making any connections.

M20811

COVER 
ASSEMBLY

HUMIDIFIER 
PAD ASSEMBLY

FEED TUBE NOZZLE

WATER 
DISTRIBUTION TRAY

HUMIDIFIER
HOUSING

THUMB 
SCREW

M12813

CLIP

CLIP

Summary of Contents for HE360A

Page 1: ...ibution tray for optimal efficiency and water usage Proven technology used for high performance humidification Narrower footprint than popular compatible model while maintaining a common humidifier pa...

Page 2: ...ged Total Comfort System Model Available HE360A Includes humidifier humidifier pad mounting template self piercing saddle valve and H908 Convertible Humidity Control Capacity At 120 F 49 C plenum temp...

Page 3: ...in wc and water pressure is no greater than 125 psi Location and Mounting IMPORTANT Mount the humidifier at least 3 in 76 mm above the furnace jacket to allow adequate space for the drain line Check...

Page 4: ...es and regulations H8908 Humidistat Wiring Connections IMPORTANT Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed If not using a current s...

Page 5: ...should reduce the accumulation of moisture and ice on the windows and in other areas of the house Some indoor activities such as cooking showering and clothes drying can cause excessive levels of hum...

Page 6: ...water nozzle back on the tray 17 Place the humidifier pad assembly in the humidifier housing and press until the assembly is seated 18 Be sure the water feed tube is placed in the guide slots of the...

Page 7: ...y Condensation on walls Turn off humidity control and water until condensation is completely evaporated Heavy condensation on windows Turn down humidity control low enough to eliminate condensation ca...

Page 8: ...ic Drive Golden Valley MN 55422 Scarboroug Ontario MiV 4V9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers HE360A POWERED FLOW THROUGH HUMIDIFIER Fig 7 Exploded vi...