5-wire special operation
5-wire special operation only with
jumper from the b- to the M-wire in
case of max. 3 devices per door
communication system are permitted.
!
The installation of a jumper between the b- and the M-wire is only permitted when ob-
serving several conditions. Regarding a solution for your special project, please con-
tact our technical hotline.
Connect the camera
Please observe the documentation of the manufacturer!
Voltage supply connection
!
The voltage supply of the PTZ camera is not realised via the PTZ camera interface
and not via the TCS:BUS
®
.
The PTZ camera is to supply separately with a power supply unit which is suitable
for the camera.
To connect the special voltage supply, the terminals
K Power Kamera
can be used
in the FBI4500.
ATTENTION
: The terminals
K Power Kamera
must not exceed 2 A / 26 V!
Note for the connection of more than one interface
!
Max. 16 interfaces and 16 cameras are permitted when using up to 5 video switches at
one TCS:BUS
®
.
Setup the PTZ camera interface as end device
If the device is installed at the end of a TCS:BUS
®
video strand, set the matching resis-