11/2012
7
TCS TürControlSysteme AG
TCS Hotline: +49 (0) 41 94 / 98 81 188
Subject to technical changes.
FAX: +49 (0) 41 94 / 98 81 29
Mail: [email protected]
PI_FBI4500-0100.doc 2A
Installation
Installation location
The PTZ camera interface is suitable for the inner and outer installation
(housing IP65).
!
When installing the device outdoors, please observe that the cable gland (M12
screw connection) must be facing downwards!
Please observe the documentation of the camera manufacturer !
Open and close the housing
Loosen the cover screws of the PTZ camera interface. Remove the cover.
Use the lower cover to mark out the four attachment holes at the corners of the housing.
!
Do not use the lower cover as drilling template as it may cause damage to the de-
vice!
Drill the marked holes and insert dowels into the wall if necessary. Screw the housing
firmly to the wall.
Guide the connection lines through the cable gland (M12 screws).
Close the housing only after the installation and configuration.
Connect the lines
Connection lines
The connection of the connection line is attained by a M12 screw connection.
Use only one cable with jacket, diameter 3.5 to 7 mm per screw connection.
Cross-sections for connection lines
Connection TCS:BUS
Permitted cross-section (diameter)
Max. number of wires per terminal contact
Connections camera
Permitted cross-section (diameter)
Max. number of wires per terminal contact
0.32
… 2.1 mm
2
(Ø 0
.3 … 1.6 mm)
each 2 x Ø 0.8 mm or 3 x Ø 0.6 mm
0.08
… 1.3 mm
2
(Ø 0.32
… 1.3 mm)
each 2 x Ø 0.8 mm or 3 x Ø 0.6 mm