Commissioning
Commissioning the system
Install the devices of the system voltage-free and completely.
The PTZ camera interface is to be connected to the TCS:BUS
®
according to the con-
nection diagram.
Check the a-, b- and P-wire against each other for short-circuits.
Connect the PTZ camera according to the connection diagram.
Switch ON the mains voltage.
The PTZ camera interface is ready for operation.
Storage in case of a voltage breakdown
The data, stored on the EEPROM storage which is integrated into the micro controller is
still available even after a voltage breakdown.
Configuration
Presettings ex works
The device is equipped with an EEPROM which stores the following device settings ex
works:
AS-address camera 1
0
Control function for moving to prepositions
239
Second AS-address for moving to preposition 2 camera 2
deactivated
Automatic Stop protocol
deactivated
Camera address
1
Type of PTZ protocol to control the camera
Pelco D
Baud rate
2400 Bd
Configuration options
Function
Manual
configo
TM
version 1.7.x
Video level
x
-
Allocate camera AS-address for moving to preposition 1
-
x
Train / delete preposition of the connected camera
-
x
Allocate control function numbers to each preposition
-
x
Allocate 2nd AS-address for moving to preposition 2
-
x
Allocate control function number for topstitching between the preposi-
tions
-
x
Determine PTZ protocol type (match with the camera type)
-
x
Activate / deactivate the sending of the automatic stop protocol, when
activating: set delay
-
x
OSD camera menu
-
x