Outlet pump cleaning (twice a year is recommended)
Tear down outlet pump
protective cover with a
blade or a coin as shown
in the
fi
gure;
Unscrew the pump
cover (beware of water
residue) and take out
clothes residue and
clean it up completely
until the blade can
rotate freely;
Fit on the pump cover
and screw it to make
sure there is no water
leakage as shown in the
fi
gure. Put on the
protective cover!
n
Pay attention to the spillover of detergent that may cause inconvenience when
adjusting (like tilting and moving, etc.) the machine (draw out the case before
adjusting).
n
A little detergent will
fl
ow into water box when drawing the case, this is normal. Try
not repeatedly opening and closing the case in case of detergent loss;
u
Use tap water or brush to wash detergent case and syphon pipe;
u
As
fi
g. b (d) shows, open the case (pick it up slowly) and take out syphon
plate (lift it up);
u
As
fi
g. a (c) shows, pull the case and press down the limit rod; pull the whole
drawer out;
u
Restore case cover and syphon pipe, and push the drawer in.
n
If there is detergent or softener residue in the case:
Routine maintenance
Caution: Beware of scald!
n
Turn off the tap!
n
Maintain the machine after the hot water is cooled in case of scald;
!