TCL Air Conditioner Service Manual
5
Technical Specifications
Model No.
TAC-24CSA/M
TAC-24CHSA/M
Type
Cooling Only
Heating Pump
Control type
Remote
Remote
Rated cooling capacity Btu/h 24,000
24,000
Rated heating capacity
Btu/h
N/A
26,000
EER for cooling
Btu/h.w
9.8
9.8
COP for heating
W/W
N/A
3.2
Moisture removal
Liters/h
2.63
2.63
High dB(A)
49
49
Med. dB(A)
46
46
Indoor noise level at
cooling
Low dB(A)
42
42
Outdoor noise level
dB(A)
58
58
Electrical Data
Power supply
220V~/50Hz
Voltage
Range
V
Cooling A
11.5
11.5
Rated current
Heating
A N/A
11.2
Cooling W
2430
1130
Rated input
Heating
W N/A
1120
Refrigerating System
Refrigerant/Charge Gram
R410A/1900g
R410A/1900g
Type Rotary
Rotary
Model ------------------
-----------------
LRA A
------
-------
Compressor
MFG -----------------
-----------------
Evaporator
Louver fin and Grooved tube type (
φ
7)
Condenser
Corrugated fin and Grooved tube type (
φ
9.53)
Expansion device
Capillary tube
Defrosting system
Microcomputer controlled reverse system
Fan System
Indoor air circulation
m
3
/h
1100
1100
Indoor fan type
Cross flow
Cross flow
Cooling rpm
1300/1200/1100
1300/1200/1100
Heating
rpm N/A
1300/1200/1100
Dry rpm
1100
1100
Indoor fan speed
H/M/L
Sleep rpm
1100
1100
Indoor fan motor output
W
12
12
Outdoor air circulation
m
3
/h
--- ---
Outdoor fan type
Propeller fan
Propeller fan
Outdoor fan speed
rpm
850
850
Outdoor fan motor output W
76 76
Connections
Refrigerant coupling
Flare type
Gas Inches
5/8 5/8
Connecting Pipe
Liquid Inches 3/
8 3/8
Connecting Wiring
Size
×
Core
number
Drainage Pipe
O.D 16mm
Others
Suitable area m
2
35~48 35~48
Indoor mm
1036
×
313
×
204
1036
×
313
×
204
Net dimensions
(W x H x D)
Outdoor
mm
890
×
307
×
660
890
×
307
×
660
Indoor kg
14
18
Net weight
Outdoor
kg
56
57
Indoor mm
1103
×
395
×
280
1103
×
395
×
280
Packing dimensions
(W x H x D)
Outdoor
mm
975
×
400
×
700
975
×
400
×
700
Indoor kg
18
18
Gross weight
Outdoor
kg 62
63
Loading Capacity
40’/40’HC 64/142/162
64/142/162