1900
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
Daytime
Area to cooled-square feet
Cooling
Primarily
4000~
6000
4000
6000
5000
6000~
8500
24000~
27000
8500~
15000~19000
19000~24000
27000~32000
11000
11000~
15000
1900
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
Band A - Occupied space above ceiling
Band B - lnsulated ceiling under attic
Band C - Non lnsulated ceiling under attic
Nighttime
Cooling
Cooling capacity required-BTU/Hr.
If area to be cooled includes a kitchen, add 1,000 BTU/Hr.
If more than two people occupy area, add 600 BTU/Hr. per person.
If only one person, subtract 600 BTU/HR.
How to read the cooling Selection Guide
1. Determine area to be cooled in sqare feet.
Locate that point on the left side of the Cooling Selection Guide.
2. Move horizontally across to Band A, B or C, according to ceiling condition in the area to be cooled as follows:
- Band A: Occupied space above ceiling
- Band B: Insulated ceiling under attic
- Band C: Non-insulated ceiling unter attic
This "band" on the Selection Guide indicates a range of BTU/Hr. capacity normally required to cool such an area.
11. The coordination coefficient of cooling capacity
You can use the cooling selection guide chart to determine the size unit best suited for the consumer's
application.
TCL Air Conditioner Service Manual
25