![TCL RT2841 Series Service Manual Download Page 11](http://html1.mh-extra.com/html/tcl/rt2841-series/rt2841-series_service-manual_4146603011.webp)
Test and Alignment Specification for RT2841 Series (v0.01).docx
Page 6 of 27
In case of starting from blanked flash, it’s necessary to write “
tcl.img”
file via factory copy in advance.
OAD Stream
(This function is not ready by SW)
To manage quicker mass reflashing on predefined DVB Channel, some licensed IBL tools ('xxx2lli.exe', 'lli2dsm.exe',
dsmmerge.exe …) from Intel byte Inc. might be necessary to create appropriate DVB SSU image. Over some predefine
settings such as repeated data block insertion, null packets size, … that are controllable in configuration file, here below
are mandatory OUI entries structure to prepare DSM-CC carousel image format:
-
export CUST_OAD_OUI
0x001C50
-
export CUST_OAD_HW_MODEL
0x5395
-
export CUST_OAD_HW_VERSION
0x0000
-
export CUST_OAD_SW_MODEL
0x0001
-
export CUST_OAD_SW_VERSION
0x00
OAD reflashing is managed within 4 steps operation: multiplex detection, DVB transfer, flashing and warm-start.
See Appendix
⑷
“How to upgrade FLASH SW by OAD”
1.3.
UART & IR Parser
To use both UART and/or IR parser, TV has to be set in Factory mode with its USB port well connected to suitable
UART device or an IR emitter device correctly facing up TV (see below “section 2.0 - Product Assembly” how to
activate “Factory key”).
The UART parser engine is enabled by sending following command “
0xE2
” from host to TV within following presets
115200
/
8
/
n
/
1
.
Once initialized, “
PS
” caption is toggle displayed on bottom left screen (“S” like Serial).
To communicate with TV depending on SIACP revision layout implementation, you need to fulfill UART/IR
commands protocol and format described on enclosed SIACP requirements document (rev. v8.31).
1.4.Project ID Modification
There are different IDs stored into the eMMC depending on different Panels settings and Models features, but
there’s only one key branching ProjectID that includes all. So it’s not recommended to modify Panel ID with Hyper
terminal as other ID features may not change!
To modify ProjectID, first of all you need to enable Factory Hotkey (See below “section 2.0-Product Assembly”). After
that, go through1950 to “
Main menu
Service menu
8-Project ID
”, then turn left or right with RCU “◄
/
►” key”
keys to suitable ID (Project name is dynamically refreshed). Restart TV.
See Appendix
⑸
“
How to change ProjectID with RCU
”
See below is the ProjectID table for reference:
MODEL-EU
ProjectID PanelID
Panel Name
MODEL-EU
ProjectID PanelID
Panel Name
Summary of Contents for RT2841 Series
Page 32: ...Test and Alignment Specification for RT2841 Series v0 01 docx Page 27 of 27 ...
Page 33: ...11 Oct 18 Page 8 nRT41 Chassis Block Diagram ...
Page 34: ...11 Oct 18 Page 9 nPower supply Block Diagram ...
Page 35: ...11 Oct 18 Page 10 nRT41 Power supply Block Diagram ...
Page 46: ...11 Oct 18 Page 23 nTrouble Shooting ...
Page 47: ...nTrouble Shooting 11 Oct 18 Page 24 ...
Page 48: ...nTrouble Shooting 11 Oct 18 Page 25 ...
Page 49: ...11 Oct 18 Page 11 nKey Test Point Main Power Supply 12V 12V Test point ...
Page 51: ...11 Oct 18 Page 13 nKey Test Point LDC1 1V5_DDR UDC1 3V3_STB to 1V5_DDR 3V3_STB STR Enable ...
Page 52: ...11 Oct 18 Page 14 LDB1 CORE 1V0 nKey Test Point 12V UDDB 12V TO 1V0 ...
Page 53: ...11 Oct 18 Page 15 LDA1 5V nKey Test Point UDA1 12V TO 5V ...
Page 57: ...11 Oct 18 Page 19 nKey Test Point PANEL_VCC 12V Q900 PANEL_VCC ...
Page 58: ...11 Oct 18 Page 20 Main Chip 1 SOC Config 2 24MHz CRYSTAL nKey Test Point Test Point ...