I. Potential for fire or burning. Do not puncture, crush, or heat the battery. Strictly avoid using
sharp tool to pry up battery. Fire extinguisher is needed for emergency.
II. The battery can be re-used after disassembly if it is normal.
III. Please be careful for the battery sticker when you are pulling out them, do not pull off the
battery sticker. If sticker is cracked when pulling out, must change new battery.
Step 8: Pry up vibrator with tweezers firstly. Disconnect sub FPC and coaxial cable with tweezers,
then pry up the sub PCBA and remove it from front casing.
Remove vibrator by Soldering iron. (
Temperature
:
Lead-free technology 330
℃
±10
℃,
time
:
2~3
seconds
)
Sub FPC
connector
Vibrator
Coaxial cable