L1
Service
Manual
TCL
Communication Ltd.
Rev.
4017A_D_E_F_X_S L1 service manual
Page
1.0
31/36
All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
3.3.2.
Charger test
When the standard charger is connected to the cell phone, check correct running of the charge indicator on
the display (refer to item 3.3.1 ).
Use the ampere meter to test the current of the charger.
1) Connect the power supply to ampere meter with adapter.
Power on adapter
2)
Connect the cables from “OUT” on other side to handset.
Power on charger
3)
Connect charger to the meter “ IN “ on the side
4) You can read the current on ampere-meter
5) The reading of the charger output should be 350 mA~550 mA
4. Software download
It is authorized to download software for the handset which needs to be updated. This downloading tool
is called
“Sugar MTK_SP”. Thus internet access is necessary. TS Website: https://css.tclmobile.cn/.
4.1 Equipments requested when download
:
⑴
A handset with full power;