L2 Repair Document
TCL
Communication Ltd.
Rev.
ALCATEL 6070K/Y/O Level 2 Repair Document
Page
1.2
21/85
All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
Cell model
CSL376776
Pack model
TLp030F1
Nominal voltage
3.84V
Battery capacity
3000mAh (Minimum)
Fully charged battery is discharged with current
0.2C from 4.40V to 3.00V
Charge
Charge method
CC - CV (Constant current - Constant voltage)
Operating temp.
0
~
10°C
10
~
45°C
45
~
60°C
Current
0.2C(Standard)
0.5C
(Max)
0.5C(Standard)
1C(Max)
0.2C(Standard)
0.5C(Max)
Limited voltage
4.40V
4.40V
4.10V
Discharge Current
0.2C(Standard)
1.5C(Max)
Cut-off voltage
3.00V
Operating temp.
-20~+60°C
Storage at different temperature
Storage temp.
Storage
term
Recovery
capacity
-20~+60°C
1 month
Refer to note*1
-20~+45°C
3 months
-20~+20°C
1 year
charge current at different voltage
<2.5V 0.2C
<3.2V 0.5C
Initial impedance
≤150 mΩ
(
@AC1kHz
)
Shipment voltage
3.88
~
3.98V
Storage relative humidity
65±20%
Note*1: The capacity recovery rate should be more than 80% under the shipment
status.
4. Software download
It is authorized to download software for the handset which needs to be updated. This downloading
tool is called
“Sugar QCT_SP”. Thus internet access is necessary. TS Website:
4.1 Equipments requested when download
⑴
A handset with full power;
⑵
PC with windows system;