MS82S-AP/LA Chassis Software Upgrade Guidance
PRELIMINARY INFORMATION ----- SUBJECT TO CHANGE
4
2.2 Factory Menu
Factory Menu
Name
Default
Description
Status
FAC
HOTKEY
OFF
Factory Menu shortcut button switch
The item must be disabled (OFF) after production
OK
WARM-
UP
OFF
OFF: Normal mode. Display blue screen when no signal. Turn to
automatically standby mode if keep the signal unavailable over
15 minutes.
ON: Aging mode. Display snow dot when no signal. The set will not
turn to standby even if the unavailability of signal
OK
ADC
>>
ADC calibration ( see details below)
OK
WHITE
BALANCE
>>
White Balance Adjustment ( see details below)
OK
SHOP
DO
It is crucial that the function is executed after production aim to clear
information of production process, ensure user cannot access to
Factory Menu after executing the item.
OK
NVM RESET
DO
Restore default value except WB and ADC data.
OK
SET FAC CH
DO
Preset the channel table of factory. Option: HZ, WX, EGYPT-EL,
ALGERIA e.g. To preset the channel table of certain factory, firstly,
choose the corresponding factory name, then press OK button of
remote control and wait until the disappearance of Factory Menu,
OK
Power On
Mode
LAST/STB
ON: the set will power on after switching on power.
STB: the set will remain standby status after switching on power.
Last: the set will turn to the status in which it lies when last switching
off.
If without requirement from certain customer,
by default, the Setting should be Last for MS82S-AP and STB for
MS82S-LA
OK
USB
UPDATE
Upgrade software. Please see details below.
OK
SW NO.
OFF
Version information of Main Software
OK
Project
Name
Product
model
OK
SIACP
Version
Serial port remote control protocol
OK
Date
Release date and time of main software
OK