10. adjust needle protrusion
Attention!
Risk of injury due to excessive needle projection. A large needle projection allows a
large insertion depth. This may result in injuries to the subcutaneous fat tissue. Always start
with a small needle projection!
Caution. The needle projection (standard 0-3.5mm) varies depending on the cartridge manufac-
turer. It may happen that the needle tips protrude slightly from the module when it is at a stand-
still. There is a risk of injury!
1. Switch on the MAGERO®.
2. Twist-lock mechanism: adjust the needle projection by loosening the handle (by turning it
clockwise by about 10°).
3. Now set the desired needle projection by carefully moving the handle forward/backward.
4. Fix the handle again by turning it counterclockwise.
5. Check whether the grip piece is firmly seated and the needle projection no longer changes.
9. putting MAGERO® into operation
1. Insert battery (see 8.).
2. Switch on: Press Power for 2 seconds (battery status is displayed in blue for 4 se-
conds, then the speed level is displayed in orange).
3. Start: Press Power briefly.
4. Adjust speed: press +/- (see 11.).
5. Stop: Press power briefly.
6. (Battery level is displayed in blue for 4 seconds).
7. Switch off: Press Power for 2 seconds.
Summary of Contents for BLACKGOLD MAGERO
Page 10: ......