LENGTH
Range: 0 - 100
The elimination process is controlled via the parameters Length and Depth. Length
determines the length of the assumed thump The thump elimination stage models
the low frequency pulse, which can be up to 12000 samples in length (with CD quali-
ty audio) and eliminates it by subtraction. A higher Length value will correct longer
thumps.
DEPTH
Range: 0 – 9
Depth determines the complexity of the thump model where a higher depth value
gives more complexity and should be used with pulses that have larger frequency vari-
ation.
METERS / LEVELS
In
Sets the Input level of the plug-in. It may be necessary to lower the input level if sig-
nals close to full scale are fed to the plug-in.
Out
Sets the Output level of the plug-in.